Literature DB >> 17265799

Aberrometry: basic science and clinical applications.

S Marcos1.   

Abstract

This paper addresses the concept, measurement and applications of wave aberrations. The ocular optics is not perfect. Apart from conventional low order aberrations (such as defocus and astigmatism) retinal images are degraded by other high order aberrations. Aberrometers typically measure ray deviations at the retinal plane, as a function of pupil position, i.e. local derivatives of the wave aberration. The paper discusses state of the art technology to measure the aberrations of the eye (cornea and crystalline lens), both monochromatic and polychromatic. The aberrometers described include the Hartmann-Shack wavefront sensor, laser ray tracing, spatially resolved refractometer or the corneal aberrations. This technology has been used to advance our understanding on several visual mechanisms, ocular conditions, and corrective methods. Applications include accommodation, myopia, aging, myopia, keratoconus, corneal refractive surgery, cataract surgery or contact lenses.

Entities:  

Mesh:

Year:  2006        PMID: 17265799

Source DB:  PubMed          Journal:  Bull Soc Belge Ophtalmol        ISSN: 0081-0746


  5 in total

1.  Assessment of aberrations and visual quality differences between myopic and astigmatic eyes before and after contact lens application.

Authors:  Mustafa Demir; Sevda Aydin Kurna; Tomris Sengor; Tugba Gencaga Atakan; Tayfun Sahin
Journal:  North Clin Istanb       Date:  2015-04-24

2.  Refractive and visual function changes in twilight conditions.

Authors:  Tatsuya Iizuka; Takushi Kawamorita; Tomoya Handa; Hitoshi Ishikawa
Journal:  PLoS One       Date:  2022-04-15       Impact factor: 3.240

Review 3.  Intraocular lens power calculation in eyes with previous corneal refractive surgery.

Authors:  Philipp Anders; Lisa-Marie Anders; Adel Barbara; Nora Szentmary; Achim Langenbucher; Zisis Gatzioufas
Journal:  Ther Adv Ophthalmol       Date:  2022-08-30

4.  Comparison of the Orbscan II topographer and the iTrace aberrometer for the measurements of keratometry and corneal diameter in myopic patients.

Authors:  Yao Chen; Xiaobo Xia
Journal:  BMC Ophthalmol       Date:  2016-03-31       Impact factor: 2.209

5.  Correlation of higher order aberrations and components of astigmatism in myopic refractive surgery candidates.

Authors:  Mehrdad Mohammadpour; Zahra Heidari; Hossein Mohammad-Rabei; Ebrahim Jafarzadehpur; Mahmoud Jabbarvand; Hassan Hashemi; Mehdi Khabazkhoob
Journal:  J Curr Ophthalmol       Date:  2016-06-20
  5 in total