Literature DB >> 17260360

Restricted field of view magnetic resonance imaging of a dynamic time series.

Laura Pisani1, Roland Bammer, Gary Glover.   

Abstract

A restricted field of view (rFOV) approach for imaging a dynamic time series of volumes of limited spatial extent within a larger subject is described. The shorter readout with rFOV-MRI can be exploited to either limit image artifacts or increase spatial resolution. To accomplish rFOV imaging of a multislice volume for a dynamic series, an outer volume suppression (OVS) preparation that saturates signal external to a cylinder through the subject is followed by slice-selective excitation and a spiral readout. The pass- and stopband efficiencies of the OVS in an agar gel phantom were 97% (+/-1.5%) and 3% (+/-1%), respectively. Profiles of the temporal signal-to-noise ratio (SNR) were measured in a phantom and an adult brain. The rFOV sequence reduced distortions from off-resonance signal and T2*-induced blurring compared to a conventional sequence. Sequence utility is demonstrated for high-resolution rFOV functional MRI (fMRI) in the visual cortex. The rFOV sequence may prove to be useful for other multislice dynamic and high-resolution imaging applications. Copyright (c) 2007 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17260360     DOI: 10.1002/mrm.21115

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  7 in total

1.  MR venography of the fetal brain using susceptibility weighted imaging.

Authors:  Jaladhar Neelavalli; Swati Mody; Lami Yeo; Pavan Kumar Jella; Steven J Korzeniewski; Sheena Saleem; Yashwanth Katkuri; Ray O Bahado-Singh; Sonia S Hassan; E Mark Haacke; Roberto Romero; Moriah E Thomason
Journal:  J Magn Reson Imaging       Date:  2013-11-25       Impact factor: 4.813

2.  Combined T2 -preparation and multidimensional outer volume suppression for coronary artery imaging with 3D cones trajectories.

Authors:  David Y Zeng; Corey A Baron; Mario O Malavé; Adam B Kerr; Phillip C Yang; Bob S Hu; Dwight G Nishimura
Journal:  Magn Reson Med       Date:  2019-11-05       Impact factor: 4.668

3.  Reducing temperature errors in transcranial MR-guided focused ultrasound using a reduced-field-of-view sequence.

Authors:  William A Grissom; Steven Allen
Journal:  Magn Reson Med       Date:  2019-09-04       Impact factor: 4.668

4.  Measuring venous blood oxygenation in fetal brain using susceptibility-weighted imaging.

Authors:  Jaladhar Neelavalli; Pavan Kumar Jella; Uday Krishnamurthy; Sagar Buch; E Mark Haacke; Lami Yeo; Swati Mody; Yashwanth Katkuri; Ray Bahado-Singh; Sonia S Hassan; Roberto Romero; Moriah E Thomason
Journal:  J Magn Reson Imaging       Date:  2014-04       Impact factor: 4.813

5.  Combined outer volume suppression and T2 preparation sequence for coronary angiography.

Authors:  Jieying Luo; Nii Okai Addy; R Reeve Ingle; Brian A Hargreaves; Bob S Hu; Dwight G Nishimura; Taehoon Shin
Journal:  Magn Reson Med       Date:  2014-12-17       Impact factor: 4.668

6.  Reduced field of view imaging using a static second-order gradient for functional MRI applications.

Authors:  Haisam Islam; Gary H Glover
Journal:  Magn Reson Med       Date:  2015-03-25       Impact factor: 4.668

7.  A comparison and evaluation of reduced-FOV methods for multi-slice 7T human imaging.

Authors:  Christopher J Wargo; Jay Moore; John C Gore
Journal:  Magn Reson Imaging       Date:  2013-07-25       Impact factor: 2.546

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.