Literature DB >> 17256544

Collection of ultrafine diesel particulate matter (DPM) in cylindrical single-stage wet electrostatic precipitators.

Phirun Saiyasitpanich1, Tim C Keener, Mingming Lu, Soon-Jai Khang, Douglas E Evans.   

Abstract

Long-term exposures to diesel particulate matter (DPM) emissions are linked to increasing adverse human health effects due to the potential association of DPM with carcinogenicity. Current diesel vehicular particulate emission regulations are based solely upon total mass concentration, albeit it is the submicrometer particles that are highly respirable and the most detrimental to human health. In this study, experiments were performed with a tubular single-stage wet electrostatic precipitator (wESP) to evaluate its performance for the removal of number-based DPM emissions. A nonroad diesel generator utilizing a low sulfur diesel fuel (500 ppmw) operating under varying load conditions was used as a stationary DPM emission source. An electrical low-pressure impactor (ELPI) was used to quantify the number concentration distributions of diesel particles in the diluted exhaust gas at each tested condition. The wESP was evaluated with respect to different operational control parameters such as applied voltage, gas residence time, etc., to determine their effect on overall collection efficiency, as well as particle size dependent collection efficiency. The results show that the total DPM number concentrations in the untreated diesel exhaust are in the magnitude of approximately108/cm(3) at all engine loads with the particle diameter modes between 20 and 40 nm. The measured collection efficiency of the wESP operating at 70 kV based on total particle numbers was 86% at 0 kW engine load and the efficiency decreased to 67% at 75 kW due to a decrease in gas residence time and an increase in particle concentrations. At a constant wESP voltage of 70 kV and at 75 kW engine load, the variation of gas residence time within the wESP from approximately 0.1 to approximately 0.4 s led to a substantial increase in the collection efficiency from 67% to 96%. In addition, collection efficiency was found to be directly related to the applied voltage, with increasing collection efficiency measured for increases in applied voltage. The collection efficiency based on particle size had a minimum for sizes between 20 and 50 nm, but at optimal wESP operating conditions it was possible to remove over 90% of all particle sizes. A comparison of measured and calculated collection efficiencies reveals that the measured values are significantly higher than the predicted values based on the well-known Deutsch equation.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17256544     DOI: 10.1021/es060887k

Source DB:  PubMed          Journal:  Environ Sci Technol        ISSN: 0013-936X            Impact factor:   9.028


  4 in total

1.  Development of a new portable air sampler based on electrostatic precipitation.

Authors:  J M Roux; R Sarda-Estève; G Delapierre; M H Nadal; C Bossuet; L Olmedo
Journal:  Environ Sci Pollut Res Int       Date:  2015-10-10       Impact factor: 4.223

2.  Continuous scavenging of broadband vibrations via omnipotent tandem triboelectric nanogenerators with cascade impact structure.

Authors:  Divij Bhatia; Hee Jae Hwang; Nghia Dinh Huynh; Sangmin Lee; Choongyeop Lee; Youngsuk Nam; Jin-Gyun Kim; Dukhyun Choi
Journal:  Sci Rep       Date:  2019-06-03       Impact factor: 4.379

Review 3.  Inhaled environmental allergens and toxicants as determinants of the asthma phenotype.

Authors:  Kristin Sokol; Sanjiv Sur; Bill T Ameredes
Journal:  Adv Exp Med Biol       Date:  2014       Impact factor: 2.622

4.  Removal of particulate matter in a tubular wet electrostatic precipitator using a water collection electrode.

Authors:  Jong-Ho Kim; Hee-Jung Yoo; You-Seong Hwang; Hyeok-Gyu Kim
Journal:  ScientificWorldJournal       Date:  2012-03-12
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.