Literature DB >> 17255423

Tracheobronchial anomalies and stenoses: detection with low-dose multidetector CT with virtual tracheobronchoscopy--comparison with flexible tracheobronchoscopy.

Christoph M Heyer1, Thomas G Nuesslein, David Jung, Soeren A Peters, Stefan P Lemburg, Christian H L Rieger, Volkmar Nicolas.   

Abstract

PURPOSE: To prospectively assess the sensitivity and specificity of low-dose multidetector computed tomography (CT) with virtual tracheobronchoscopy (VT) for evaluation of suspected airway stenoses and/or abnormalities by using flexible tracheobronchoscopy (FT) as the reference standard.
MATERIALS AND METHODS: The study was approved by the local ethics committee; parental consent was obtained. Forty-five patients with clinically and/or radiographically suspected tracheobronchial stenosis and/or anomaly underwent FT and contrast material-enhanced single-phase multidetector CT with VT. CT was performed with an age- and weight-adjusted low-dose protocol: 120 or 80 kV; 120 or 60 mA; collimation, 1.5 or 0.75 mm; gantry rotation, 0.5 second. Mean effective dose was calculated for all examinations. Postprocessing was performed with surface rendering of VT images and multiplanar reformations. CT images were analyzed in consensus by two radiologists who were blinded to FT results. Statistical analysis was performed with 2 x 2 contingency tables; 95% confidence intervals (CIs) were calculated with the Blyth-Still-Casella procedure.
RESULTS: Mean patient age was 4.4 years (range, 2 months to 16 years; 53% male patients). Tracheobronchial narrowing and/or abnormality were depicted at FT in 38 of 45 patients. In 33 of 38 patients, multidetector CT with VT depicted a tracheobronchial narrowing and/or anomaly. In 10 of 38 patients, tracheobronchial stenosis was induced by vascular anomalies. Five patients with normal findings at multidetector CT with VT had tracheobronchomalacia with inspiratory airway stenosis at FT. Sensitivity and specificity of CT with VT were 86.8% (95% CI: 73.3%, 94.7%) and 85.7% (95% CI: 44.6%, 99.3%), respectively. Positive and negative predictive values were 97.1% (95% CI: 84.9%, 99.9%) and 54.5% (95% CI: 25.0%, 80.0%), respectively. Overall accuracy was 86.7% (95% CI: 74.3%, 94.0%). Mean effective dose was 1.1 mSv (range, 0.5-1.8 mSv).
CONCLUSION: Multidetector CT with VT with a low-dose protocol had high sensitivity and specificity for depiction of tracheobronchial narrowings and/or anomalies. However, tracheal narrowing due to tracheobronchomalacia was difficult to diagnose at single-phase multidetector CT with VT. (c) RSNA, 2007.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17255423     DOI: 10.1148/radiol.2422060153

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  12 in total

1.  Flexible bronchoscopy contribution in the approach of diagnosis and treatment of children's respiratory diseases: the experience of a unique pediatric unit in Tunisia.

Authors:  Samia Hamouda; Amal Oueslati; Imen Belhadj; Fatma Khalsi; Faten Tinsa; Khadija Boussetta
Journal:  Afr Health Sci       Date:  2016-03       Impact factor: 0.927

Review 2.  Pathophysiology and clinical evaluation of the patient with unexplained persistent dyspnea.

Authors:  Andi Hudler; Fernando Holguin; Meghan Althoff; Anne Fuhlbrigge; Sunita Sharma
Journal:  Expert Rev Respir Med       Date:  2022-01-20       Impact factor: 4.300

3.  Virtual and fiber-optic bronchoscopy in patients with indication for tracheobronchial evaluation.

Authors:  Fulya Adali; Atilla Uysal; Sibel Bayramoglu; Nurten Turan Guner; Gulizar Yilmaz; Tan Cimilli
Journal:  Ann Thorac Med       Date:  2010-04       Impact factor: 2.219

4.  Outcomes of aortopexy for patients with congenital heart disease.

Authors:  Sang-Yun Lee; Soo-Jin Kim; Jae-Suk Baek; Jae-Gun Kwak; Chul Lee; Chang-Ha Lee; Yang-Min Kim
Journal:  Pediatr Cardiol       Date:  2013-03-08       Impact factor: 1.655

5.  Comparison of virtual and fiberoptic bronchoscopy in the management of airway stenosis.

Authors:  Zsuzsa Mark; Gabor Bajzik; Andrea Nagy; Peter Bogner; Imre Repa; Janos Strausz
Journal:  Pathol Oncol Res       Date:  2008-06-10       Impact factor: 3.201

6.  Evaluation of tracheal bronchus in Chinese children using multidetector CT.

Authors:  Zhu Ming; Zhang Lin
Journal:  Pediatr Radiol       Date:  2007-10-02

7.  Evaluation of tracheal stenosis: comparison between computed tomography virtual tracheobronchoscopy with multiplanar reformatting, flexible tracheofiberoscopy and intra-operative findings.

Authors:  Kamal Morshed; Agnieszka Trojanowska; Marcin Szymański; Piotr Trojanowski; Anna Szymańska; Agata Smoleń; Andrzej Drop
Journal:  Eur Arch Otorhinolaryngol       Date:  2010-09-17       Impact factor: 2.503

8.  Multiplanar Reconstructed Thoracic CT Bronchoscopy in Endobronchial Tuberculosis.

Authors:  Fariba Rezaeetalab; Donya Farrokh; Behrouz Zandiee
Journal:  Iran J Radiol       Date:  2012-11-20       Impact factor: 0.212

9.  Usefulness of computed tomography virtual bronchoscopy in the evaluation of bronchi divisions.

Authors:  Michał Adamczyk; Grzegorz Tomaszewski; Patrycja Naumczyk; Ewa Kluczewska; Jerzy Walecki
Journal:  Pol J Radiol       Date:  2013-01

10.  Detection of airway anomalies in pediatric patients with cardiovascular anomalies with low dose prospective ECG-gated dual-source CT.

Authors:  Hui Jiao; Zhuodong Xu; Lebin Wu; Zhaoping Cheng; Xiaopeng Ji; Hai Zhong; Chen Meng
Journal:  PLoS One       Date:  2013-12-06       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.