Literature DB >> 17255408

PET/CT: form and function.

Todd M Blodgett1, Carolyn C Meltzer, David W Townsend.   

Abstract

Functional imaging with positron emission tomography (PET) is playing an increasingly important role in the diagnosis and staging of malignant disease, image-guided therapy planning, and treatment monitoring. PET with the labeled glucose analogue fluorine 18 fluorodeoxyglucose (FDG) is a relatively recent addition to the medical technology for imaging of cancer, and FDG PET complements the more conventional anatomic imaging modalities of computed tomography (CT) and magnetic resonance imaging. CT is complementary in the sense that it provides accurate localization of organs and lesions, while PET maps both normal and abnormal tissue function. When combined, the two modalities can help both identify and localize functional abnormalities. Attempts to align CT and PET data sets with fusion software are generally successful in the brain; other areas of the body is more challenging, owing to the increased number of degrees of freedom between the two data sets. These challenges have recently been addressed by the introduction of the combined PET/CT scanner, a hardware-oriented approach to image fusion. With such a device, accurately registered anatomic and functional images can be acquired for each patient in a single scanning session. Currently, over 800 combined PET/CT scanners are installed in medical institutions worldwide, many of them for the diagnosis and staging of malignant disease and increasingly for monitoring of the response to therapy. This review will describe some of the most recent technologic developments in PET/CT instrumentation and the clinical indications for which combined PET/CT has been shown to be more useful than PET and CT performed separately. (c) RSNA, 2007.

Entities:  

Mesh:

Year:  2007        PMID: 17255408     DOI: 10.1148/radiol.2422051113

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  95 in total

1.  PET probes and oncological surgery: a productive new marriage for nuclear medicine?

Authors:  Orazio Schillaci
Journal:  Eur J Nucl Med Mol Imaging       Date:  2007-10       Impact factor: 9.236

Review 2.  Novel detector technology for clinical PET.

Authors:  Roger Lecomte
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-03       Impact factor: 9.236

3.  Multimodal nanoprobes for radionuclide and five-color near-infrared optical lymphatic imaging.

Authors:  Hisataka Kobayashi; Yoshinori Koyama; Tristan Barrett; Yukihiro Hama; Celeste A S Regino; In Soo Shin; Beom-Su Jang; Nhat Le; Chang H Paik; Peter L Choyke; Yasuteru Urano
Journal:  ACS Nano       Date:  2007-11       Impact factor: 15.881

4.  Aortic inflammation, as assessed by hybrid FDG-PET/CT imaging, is associated with enhanced aortic stiffness in addition to concurrent calcification.

Authors:  Laure Joly; Wassila Djaballah; Gregory Koehl; Damien Mandry; Gilles Dolivet; Pierre-Yves Marie; Athanase Benetos
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-01-30       Impact factor: 9.236

Review 5.  Content-based medical image retrieval: a survey of applications to multidimensional and multimodality data.

Authors:  Ashnil Kumar; Jinman Kim; Weidong Cai; Michael Fulham; Dagan Feng
Journal:  J Digit Imaging       Date:  2013-12       Impact factor: 4.056

6.  Optimization of a Collagen-Targeted PET Probe for Molecular Imaging of Pulmonary Fibrosis.

Authors:  Pauline Désogère; Luis F Tapias; Tyson A Rietz; Nicholas Rotile; Francesco Blasi; Helen Day; Justin Elliott; Bryan C Fuchs; Michael Lanuti; Peter Caravan
Journal:  J Nucl Med       Date:  2017-06-13       Impact factor: 10.057

7.  Analysis of cancer metabolism by imaging hyperpolarized nuclei: prospects for translation to clinical research.

Authors:  John Kurhanewicz; Daniel B Vigneron; Kevin Brindle; Eduard Y Chekmenev; Arnaud Comment; Charles H Cunningham; Ralph J Deberardinis; Gary G Green; Martin O Leach; Sunder S Rajan; Rahim R Rizi; Brian D Ross; Warren S Warren; Craig R Malloy
Journal:  Neoplasia       Date:  2011-02       Impact factor: 5.715

Review 8.  Metabolic positron emission tomography imaging in cancer detection and therapy response.

Authors:  Aizhi Zhu; Daniel Lee; Hyunsuk Shim
Journal:  Semin Oncol       Date:  2011-02       Impact factor: 4.929

9.  Respiratory-gated PET/CT versus delayed images for the quantitative evaluation of lower pulmonary and hepatic lesions.

Authors:  Abdel K Tahari; Martin A Lodge; Richard L Wahl
Journal:  J Med Imaging Radiat Oncol       Date:  2014-01-20       Impact factor: 1.735

Review 10.  Current and future uses of neuroimaging for cognitively impaired patients.

Authors:  Gary W Small; Susan Y Bookheimer; Paul M Thompson; Greg M Cole; S-C Huang; Vladimir Kepe; Jorge R Barrio
Journal:  Lancet Neurol       Date:  2008-02       Impact factor: 44.182

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.