Literature DB >> 17254904

The accuracy of goniometric measurements of proximal interphalangeal joints in fresh cadavers: comparison between methods of measurement, types of goniometers, and fingers.

Masami Kato1, Ayumu Echigo, Hisaaki Ohta, Sumio Ishiai, Mitsuhiro Aoki, Sadako Tsubota, Eiichi Uchiyama.   

Abstract

This study evaluates the accuracy of goniometric measurement of fixated proximal interphalangeal (PIP) joints using fresh cadavers. Sixteen fingers in four right hands were evaluated. Angles of PIP joints obtained by three examiners, two methods (lateral, dorsal), three goniometers (plastic A, B, and a metal model), and four different fingers were compared for the accuracy of measurement. The difference of angles obtained from goniometric measurement and x-ray films of cadaver fingers was defined as "angle discrepancy." Analysis of interrater reliability proved that there was a high correlation coefficient between examiners. With the lateral method, no statistically significant difference in angle discrepancy between goniometers was observed. On the other hand, with the dorsal method, the angle discrepancy of plastic A was statistically significantly greater than plastic B in the results of two examiners (p<0.05). In both lateral and dorsal methods, the angle discrepancy of the index and ring fingers is statistically significantly greater than that of the middle and little fingers. We recommend use of the lateral method with any of the three goniometers for measurement of PIP range of motion. Goniometers with short arms are considered to be suitable for the dorsal method.

Entities:  

Mesh:

Year:  2007        PMID: 17254904     DOI: 10.1197/j.jht.2006.11.015

Source DB:  PubMed          Journal:  J Hand Ther        ISSN: 0894-1130            Impact factor:   1.950


  6 in total

1.  Viability of Hand and Wrist Photogoniometry.

Authors:  Clifton G Meals; Rebecca J Saunders; Sameer Desale; Kenneth R Means
Journal:  Hand (N Y)       Date:  2017-04-09

2.  Visual Estimation of Dupuytren's Flexion Contractures-A Prospective Comparative Trial.

Authors:  Joseph P Corkum; Joshua A Gillis; David T Tang
Journal:  Plast Surg (Oakv)       Date:  2018-01-09       Impact factor: 0.947

3.  The effect of proficiency level on measurement error of range of motion.

Authors:  Kazunori Akizuki; Kazuto Yamaguchi; Yoshiyuki Morita; Yukari Ohashi
Journal:  J Phys Ther Sci       Date:  2016-09-29

4.  Hand Extension Robot Orthosis (HERO) Grip Glove: enabling independence amongst persons with severe hand impairments after stroke.

Authors:  Aaron Yurkewich; Illya J Kozak; Debbie Hebert; Rosalie H Wang; Alex Mihailidis
Journal:  J Neuroeng Rehabil       Date:  2020-02-26       Impact factor: 4.262

5.  Measurement of finger joint angle using stretchable carbon nanotube strain sensor.

Authors:  Jin Woo Park; Taehoon Kim; Daesik Kim; Yongtaek Hong; Hyun Sik Gong
Journal:  PLoS One       Date:  2019-11-14       Impact factor: 3.240

6.  Reliability of the standard goniometry and diagrammatic recording of finger joint angles: a comparative study with healthy subjects and non-professional raters.

Authors:  Valdas Macionis
Journal:  BMC Musculoskelet Disord       Date:  2013-01-09       Impact factor: 2.362

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.