PURPOSE: The primary objective was to compare measures of bulbar redness objectively using a photometric method with standard grading methods. Measures of redness were made on 24 participants wearing asilicone hydrogel contact lens in one eye for overnight wear. This report compares hyperaemia after 1 week of daily wear (baseline) with redness measured after 6 months of overnight wear. METHOD: A new method of objectively measuring bulbar conjunctival redness was performed using the Spectrascan650 Photometer by Photo Research under fixed illumination. Photometric measures in CIEu(*) chromaticity values involve the measurement of chromaticity, a physical analogue of redness, greenness and blueness in the image. This method was validated in Part 1 of the study using repeated measurements on the photographic CCLRU scale. In Part 2 of the study, the photographic grading scale (CCLRU) from 0 (none) to 100 (extreme) was used to make the comparison. RESULTS: Part 1 indicated that the photometer provides a repeatable and reliable measure of bulbar redness (CCC=0.989). A moderately strong and significant correlation was found between the CIEu(*) chromaticity values and the analogue data (R=0.795, p=0.000) at each measurement session (from baseline to 1 day, 1 week, and 1, 3 and 6 months of overnight wear). CONCLUSIONS: This new standardized and objective method of measuring bulbar redness has great potential to replace subjective grading scales, especially with multi-centre studies, where variability between investigators occurs. This method may also detect smaller changes between visits or between eyes.
RCT Entities:
PURPOSE: The primary objective was to compare measures of bulbar redness objectively using a photometric method with standard grading methods. Measures of redness were made on 24 participants wearing a silicone hydrogel contact lens in one eye for overnight wear. This report compares hyperaemia after 1 week of daily wear (baseline) with redness measured after 6 months of overnight wear. METHOD: A new method of objectively measuring bulbar conjunctival redness was performed using the Spectrascan650 Photometer by Photo Research under fixed illumination. Photometric measures in CIEu(*) chromaticity values involve the measurement of chromaticity, a physical analogue of redness, greenness and blueness in the image. This method was validated in Part 1 of the study using repeated measurements on the photographic CCLRU scale. In Part 2 of the study, the photographic grading scale (CCLRU) from 0 (none) to 100 (extreme) was used to make the comparison. RESULTS: Part 1 indicated that the photometer provides a repeatable and reliable measure of bulbar redness (CCC=0.989). A moderately strong and significant correlation was found between the CIEu(*) chromaticity values and the analogue data (R=0.795, p=0.000) at each measurement session (from baseline to 1 day, 1 week, and 1, 3 and 6 months of overnight wear). CONCLUSIONS: This new standardized and objective method of measuring bulbar redness has great potential to replace subjective grading scales, especially with multi-centre studies, where variability between investigators occurs. This method may also detect smaller changes between visits or between eyes.
Authors: Ilaria Macchi; Vatinee Y Bunya; Mina Massaro-Giordano; Richard A Stone; Maureen G Maguire; Yuanjie Zheng; Min Chen; James Gee; Eli Smith; Ebenezer Daniel Journal: Ocul Surf Date: 2018-06-06 Impact factor: 5.033
Authors: Francisco Amparo; Jia Yin; Antonio Di Zazzo; Tulio Abud; Ula V Jurkunas; Pedram Hamrah; Reza Dana Journal: Transl Vis Sci Technol Date: 2017-07-20 Impact factor: 3.283
Authors: Rohan Bir Singh; Lingjia Liu; Sonia Anchouche; Ann Yung; Sharad K Mittal; Tomas Blanco; Thomas H Dohlman; Jia Yin; Reza Dana Journal: Ocul Surf Date: 2021-05-16 Impact factor: 6.268
Authors: Rohan Bir Singh; Lingjia Liu; Ann Yung; Sonia Anchouche; Sharad K Mittal; Tomas Blanco; Thomas H Dohlman; Jia Yin; Reza Dana Journal: Ocul Surf Date: 2021-05-15 Impact factor: 6.268
Authors: Cameron K Postnikoff; Andrew D Pucker; John Laurent; Carrie Huisingh; Gerald McGwin; Jason J Nichols Journal: Invest Ophthalmol Vis Sci Date: 2019-01-02 Impact factor: 4.799