Literature DB >> 17252607

Mesophilic and thermophilic biotreatment of BTEX-polluted air in reactors.

Balsam T Mohammad1, María C Veiga, Christian Kennes.   

Abstract

This study compares the removal of a mixture of benzene, toluene, ethylbenzene, and all three xylene isomers (BTEX) in mesophilic and thermophilic (50 degrees C) bioreactors. In the mesophilic reactor fungi became dominant after long-term operation, while bacteria dominated in the thermophilic unit. Microbial acclimation was achieved by exposing the biofilters to initial BTEX loads of 2-15 g m(-3) h(-1), at an empty bed residence time of 96 s. After adaptation, the elimination capacities ranged from 3 to 188 g m(-3) h(-1), depending on the inlet load, for the mesophilic biofilter with removal efficiencies reaching 96%. On the other hand, in the thermophilic reactor the average removal efficiency was 83% with a maximum elimination capacity of 218 g m(-3) h(-1). There was a clear positive relationship between temperature gradients as well as CO(2) production and elimination capacities across the biofilters. The gas phase was sampled at different depths along the reactors observing that the percentage pollutant removal in each section was strongly dependant on the load applied. The fate of individual alkylbenzene compounds was checked, showing the unusually high biodegradation rate of benzene at high loads under thermophilic conditions (100%) compared to its very low removal in the mesophilic reactor at such load (<10%). Such difference was less pronounced for the other pollutants. After 210 days of operation, the dry biomass content for the mesophilic and thermophilic reactors were 0.300 and 0.114 g g(-1) (support), respectively, reaching higher removals under thermophilic conditions with a lower biomass accumulation, that is, lower pressure drop. (c) 2007 Wiley Periodicals, Inc.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17252607     DOI: 10.1002/bit.21350

Source DB:  PubMed          Journal:  Biotechnol Bioeng        ISSN: 0006-3592            Impact factor:   4.530


  2 in total

Review 1.  Biological technologies for the removal of sulfur containing compounds from waste streams: bioreactors and microbial characteristics.

Authors:  Lin Li; Jingying Zhang; Jian Lin; Junxin Liu
Journal:  World J Microbiol Biotechnol       Date:  2015-08-07       Impact factor: 3.312

2.  Simultaneous biodegradation of BTX by isolated degrading bacterial strains in a newly designed modulated bio-scrubber assisted to airlift parallel bioreactors.

Authors:  Hamed Nayyeri; Hossein Ghanavati; Hossein Mazaheri; Ali Hassani Joshaghani
Journal:  J Environ Health Sci Eng       Date:  2022-01-07
  2 in total