Slow-releasing tranilast in polytetrafluoroethylene/polylactide-co-glycolide laminate delays adjustment after strabismus surgery in rabbit model.

Min Joung Lee1, Su-Eon Jin, Chong-Kook Kim, Ho-Kyung Choung, Jin Wook Jeoung, Hwa Jung Kim, Gheeyoung Choe, Jeong-Min Hwang.   

Abstract

PURPOSE: To determine the usefulness of slow-releasing tranilast in polytetrafluoroethylene/polylactide-co-glycolide (PTFE/PLGA) laminate for delayed adjustable strabismus surgery.
METHODS: A prospective, masked-observer, controlled study was performed in 25 rabbits. Fifty rabbit eyes were divided randomly into three groups. After a recession of the superior rectus muscle (SRM), a PTFE/PLGA laminate containing tranilast, PTFE alone, or balanced salt solution was applied beneath and over the SRM in the PTFE/PLGA-tranilast group (group P-T), the PTFE group (group P), and the control group, respectively. Delayed adjustment was performed by a masked observer once on each SRM 3 or 5 weeks after surgery. Adjustability, adjustment lengths, forces required, and adhesion degrees were evaluated.
RESULTS: In the control group, adjustment was impossible in any eye 3 or 5 weeks after surgery. In group P, adjustment was possible in 5 of 8 eyes 3 weeks after surgery and in 5 of 10 eyes 5 weeks after surgery. In group P-T, adjustment was possible in 8 of 10 eyes 3 and 5 weeks after surgery. On comparing adjustability, a significant difference was observed between group P-T and the control group 3 and 5 weeks after surgery (P = 0.006, P = 0.006, respectively). A significant difference was observed between group P-T and the control group (P = 0.016) in terms of adhesion between SRMs and conjunctivae 5 weeks after surgery.
CONCLUSIONS: Slow-releasing tranilast in PTFE/PLGA was found to reduce adhesion and allowed delayed adjustment in most eyes for up to 5 weeks after surgery.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17251468     DOI: 10.1167/iovs.06-0775

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  3 in total

Review 1.  Adjustable suture strabismus surgery.

Authors:  B R Nihalani; D G Hunter
Journal:  Eye (Lond)       Date:  2011-07-15       Impact factor: 3.775

2.  Effective treatment for prevention of post-operative adhesion after strabismus surgery in experimental rabbit model: 0.5 % tranilast ophthalmic solution.

Authors:  Sang Uk Choi; Kyoung Woo Kim; Nam Ju Moon
Journal:  BMC Ophthalmol       Date:  2016-09-21       Impact factor: 2.209

3.  Development of Sustained-Release Ophthalmic Formulation Based on Tranilast Solid Nanoparticles.

Authors:  Misa Minami; Ryotaro Seiriki; Hiroko Otake; Yosuke Nakazawa; Kazutaka Kanai; Tadatoshi Tanino; Noriaki Nagai
Journal:  Materials (Basel)       Date:  2020-04-03       Impact factor: 3.623

  3 in total