The effects of fresh gas flow on the amount of sevoflurane vaporized during 1 minimum alveolar concentration anaesthesia for day surgery: a clinical study.

K Ekbom1, H Assareh, R E Anderson, J G Jakobsson.   

Abstract

BACKGROUND: Even small costs per case can become economically significant in high volume day surgical units. While general anaesthesia with higher fresh gas flow rates has technical advantages, they result in higher costs. The aim of the present study was to evaluate drug consumption and direct costs related to variations in the fresh gas flow and use of nitrous oxide at a 1 minimum alveolar concentration (MAC) sevoflurane end-tidal anaesthesia for day surgery.
METHODS: Thirty-two ASA I-II patients undergoing elective day surgery under general anaesthesia [14 (10-21) min] were studied. Induction was with propofol and fentanyl 100 microg. After laryngeal mask airway placement, patients were randomized to one of four different fresh gas flows: 1 or 2 l/min oxygen in air (50% oxygen), 3 l/min (33% oxygen), or 3 l/min oxygen in nitrous oxide (33% oxygen). Anaesthesia was maintained at 1 MAC. The vaporizer was weighed before and after each procedure. The primary study variable was the sevoflurane utilization per minute.
RESULTS: Sevoflurane utilization increased with increasing fresh gas flow for oxygen in air (r2 = 0.89). The nitrous oxide in oxygen group had the lowest sevoflurane utilization, even compared with the lowest oxygen in air group (0.36 vs. 0.48 g/min).
CONCLUSION: Sevoflurane utilization during 1 MAC anaesthesia increases linearly with fresh gas flow and is still higher than when nitrous oxide is used even with very low fresh gas flow rates. Direct inhaled anaesthesia-related costs are consequently 20% higher than when nitrous oxide is used, even for the lowest oxygen in air fresh gas flows.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17250746     DOI: 10.1111/j.1399-6576.2006.01235.x

Source DB:  PubMed          Journal:  Acta Anaesthesiol Scand        ISSN: 0001-5172            Impact factor:   2.105


  5 in total

1.  Anaesthetic gas monitoring comparison between two side-stream monitors.

Authors:  H Heijbel; J Ostblom; M Brattwall; Jan Jakobsson
Journal:  J Clin Monit Comput       Date:  2010-03-18       Impact factor: 2.502

2.  Comparison of the Effects of Minimal and High-Flow Anaesthesia on Cerebral Perfusion During Septorhinoplasty.

Authors:  Leyla Kazancıoğlu; Şule Batçık; Başar Erdivanlı; Ahmet Şen; Engin Dursun
Journal:  Turk J Anaesthesiol Reanim       Date:  2019-02-01

3.  The effect of low fresh gas flow rate on sevoflurane consumption.

Authors:  Ho-Geol Ryu; Ji-Hyun Lee; Kyung-Ku Lee; Nam-Su Gil; Chong Soo Kim; Sung-Eun Sim; Sang Chul Lee; Seong-Won Min
Journal:  Korean J Anesthesiol       Date:  2011-02-25

4.  Cost analysis of three techniques of administering sevoflurane.

Authors:  Asha Tyagi; Vineeta Venkateswaran; Ajai Kumar Jain; Uttam Chandra Verma
Journal:  Anesthesiol Res Pract       Date:  2014-10-29

5.  Analyzing Volatile Anesthetic Consumption by Auditing Fresh Gas Flow: An Observational Study at an Academic Hospital.

Authors:  Luis Tollinche; KaySee Tan; Austin Han; Leslie Ojea; Cindy Yeoh
Journal:  Int J Anesth Anesth       Date:  2018-04-26
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.