Literature DB >> 17244218

Computerized calculation scheme for retinal image size after implantation of toric intraocular lenses.

Achim Langenbucher1, Anja Viestenz, Berthold Seitz, Holger Brünner.   

Abstract

PURPOSE: To describe a paraxial computing scheme for tracing an axial pencil of rays through the 'optical system eye' containing astigmatic surfaces with their axes at random.
METHODS: Two rays (-10 prism diopters from vertical and horizontal) are traced through the uncorrected and corrected eye. In the uncorrected eye one specific ray is selected from the pencil of rays, which passes through the pupil center. In the corrected eye any ray can be traced through the eye. From the slope angle, the intersection of the ray with the refractive surface and the refraction the slope angle of the exiting ray is determined and the ray is traced to the subsequent surface. From both rays traced through the eye an ellipse is fitted to the image to characterize the image distortion of an circular object. EXAMPLE: Assumptions: target refraction -0.5-1.0D/A = 90 degrees at 14 mm, corneal refraction 42.5 + 3.5D/A = 15 degrees, axial length 23.6 mm, IOL position 4.6 mm, central lens thickness 0.8 mm, refractive index 1.42, front/back surface of the toric IOL 10.0 D/7.14 + 6.47D/A = 101.8 degrees. The vertical incident ray was imaged to (x, y) = (0.0055 mm, -1.6470 mm)/(0.0067 mm, -1.6531 mm) in the uncorrected/corrected eye. The horizontal incident ray was imaged to (x, y) = (1.6266 mm, -0.0055 mm)/(1.6001 mm, -0.0067 mm) in the uncorrected/corrected eye. The ellipse (semi-major/semi-minor meridian) fitted to the conjugate image of a circle sized 1.648 mm/1.625 mm in an orientation 14.2 degrees in the uncorrected and 1.654 mm/1.599 mm in an orientation 7.1 degrees in the corrected eye.
CONCLUSION: This concept may be relevant for the assessment of aniseikonia after implantation of toric intraocular lenses for correction of high corneal astigmatism.

Entities:  

Mesh:

Year:  2007        PMID: 17244218     DOI: 10.1111/j.1600-0420.2006.00721.x

Source DB:  PubMed          Journal:  Acta Ophthalmol Scand        ISSN: 1395-3907


  8 in total

1.  Astigmatism and optical coherence tomography measurements.

Authors:  Young Hoon Hwang; Sang Mok Lee; Yong Yeon Kim; Jong Yeon Lee; Chungkwon Yoo
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2011-08-23       Impact factor: 3.117

Review 2.  Factors Associated with Changes in Peripapillary Retinal Nerve Fibre Layer Thickness in Healthy Myopic Eyes.

Authors:  Jianli Du; Yang Du; Yanyan Xue; He Wang; Yaping Li
Journal:  J Ophthalmol       Date:  2021-12-27       Impact factor: 1.909

Review 3.  [Toric IOLs after cataract surgery and refractive lens exchange].

Authors:  G U Auffarth; T M Rabsilber
Journal:  Ophthalmologe       Date:  2007-12       Impact factor: 1.059

4.  The Relationship Between Keratoconus Stage and the Thickness of the Retinal Layers

Authors:  Cemal Özsaygılı; Yener Yıldırım
Journal:  Turk J Ophthalmol       Date:  2021-04-29

5.  The influence of corneal astigmatism on retinal nerve fiber layer thickness and optic nerve head parameter measurements by spectral-domain optical coherence tomography.

Authors:  Lin Liu; Jun Zou; Hui Huang; Jian-guo Yang; Shao-rong Chen
Journal:  Diagn Pathol       Date:  2012-05-23       Impact factor: 2.644

Review 6.  [Toric intraocular lenses and correction of astigmatism].

Authors:  Arne Viestenz; S Walter; Anja Viestenz; W Behrens-Baumann; A Langenbucher
Journal:  Ophthalmologe       Date:  2007-07       Impact factor: 1.174

7.  [Monte Carlo simulation of biometric effect sizes and their influence on the translational ratio of corneal astigmatism in the cylinders of toric intraocular lenses].

Authors:  Achim Langenbucher; Jens Schrecker; Michael Schwemm; Timo Eppig; S Schröder; Nóra Szentmáry
Journal:  Ophthalmologe       Date:  2021-06       Impact factor: 1.059

8.  [Simple method to estimate object to image magnification and aniseikonia following cataract surgery].

Authors:  Achim Langenbucher; Peter Hoffmann; Jascha Wendelstein; Nóra Szentmáry
Journal:  Ophthalmologe       Date:  2021-06-01       Impact factor: 1.059

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.