[Internal jugular vein cannulation guided by ultrasonography in pediatric patients undergoing cardiovascular surgery].

Sadahei Denda1, Takashi Mochida, Miki Taneoka, Hiroyuki Honda, Yasushi Kitahara, Hironobu Nishimaki.   

Abstract

BACKGROUND: Central venous catheterization is essential for the anesthetic management of operations for congenital heart diseases. We prospectively examined the usefulness of ultrasonography in internal jugular vein catheterization in infants.
METHODS: Internal jugular vein cannulation was guided using an ultrasound image scanner in 96 pediatric cardiac patients. We investigated the rate of successful catheterizations, the number of attempts, the time from venipuncture to wire insertion, and the laterality of internal jugular vein diameters.
RESULTS: The success rate in all 96 patients was 95.8% with no carotid artery puncture. Patients younger than 12 month of age had success rates of 90%. In patients younger than 1 month of age and with weights less than 3.4 kg, the success rate was 76.9%. The time from venipuncture to proper wire insertion in the first attempt (55.2%) was 50.8+/-18.9s; 157.3 +/-56.4s for second attempt (18.8%) ; 285.7+/-165.7s for third attempt (7.6%) ; 346.0+/-98.4s for fourth attempt (5.5%) : and 510.0+/-98.4s for fifth attempt (2.1%). The time requited was 1404.5+/-518.4s for attempts that required more than seven passes. Cannulations in four cases were unsuccessful because the image of the internal jugular vein was difficult to visualize. The left internal jugular vein diameter was larger than the right in 40 cases. In three unsuccessful cases, the diameter was less than 4.5 mm.
CONCLUSIONS: Internal jugular vein cannulation guided by ultrasonography can be performed safely and quickly in pediatric patients.

Entities:  

Mesh:

Year:  2007        PMID: 17243648

Source DB:  PubMed          Journal:  Masui        ISSN: 0021-4892


  2 in total

1.  Ultrasound guided vascular access in pediatric cardiac critical care.

Authors:  Abdulraouf M Z Jijeh; Ghassan Shaath; Mohamed S Kabbani; Mahmoud Elbarbary; Sameh Ismail
Journal:  J Saudi Heart Assoc       Date:  2014-05-04

2.  Safety and efficacy of ultrasound assistance during internal jugular vein cannulation in neurosurgical infants.

Authors:  M Lamperti; D Caldiroli; P Cortellazzi; D Vailati; A Pedicelli; F Tosi; M Piastra; D Pietrini
Journal:  Intensive Care Med       Date:  2008-07-11       Impact factor: 17.440

  2 in total