Literature DB >> 17243587

The effects of flow dispersion and cardiac pulsation in arterial spin labeling.

Wen-Chau Wu1, Yousef Mazaheri, Eric C Wong.   

Abstract

The blood in the carotid arteries exhibits time-varying flow velocity as a function of cardiac phases. Despite this flow velocity variation, most current methods set forth for the analysis of arterial spin labeling (ASL) data have assumed that the tagged blood is delivered from the tagging region to the imaging region via simple plug flow, i.e., a single transit delay (deltat). In this study, we used a pulse oximeter to synchronize image acquisition at systole and diastole separately. The deltat dispersion was modeled with a Gaussian distribution and the effect of cardiac pulsation upon the ASL signal was evaluated on five healthy volunteers. ASL signals were collected at a series of inflow times (TI) using PICORE QUIPSS II: TR/TE/TI1 = 2400/3.2/700 ms, TI = {300, 500, 700, 900, 1100, 1300, 1500} ms, matrix size = 64 x 64, repetition = 100. Transit delay was found significantly shorter in systolic tag than diastolic tag (paired student's t-test, p < 0.001; mean difference across subjects = 54 ms). When the tag was applied in late systole, the ASL signal arrived in the target brain slice earlier, and was higher by 16% with TI = 700 ms. Intervoxel dispersion (-350 ms) dominated over intravoxel dispersion (< 200 ms). The disparity of ASL signals found between systolic and diastolic tags indicated that ASL imaging was sensitive to cardiac pulsations. We conclude that both flow dispersion and fluctuations in the ASL signal due to cardiac pulsations are significant.

Mesh:

Substances:

Year:  2007        PMID: 17243587     DOI: 10.1109/TMI.2006.886807

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  15 in total

1.  Denoising of arterial spin labeling data: wavelet-domain filtering compared with Gaussian smoothing.

Authors:  Adnan Bibic; Linda Knutsson; Freddy Ståhlberg; Ronnie Wirestam
Journal:  MAGMA       Date:  2010-04-28       Impact factor: 2.310

2.  Cardiac-triggered pseudo-continuous arterial-spin-labeling: A cost-effective scheme to further enhance the reliability of arterial-spin-labeling MRI.

Authors:  Yang Li; Deng Mao; Zhiqiang Li; Michael Schär; Jay J Pillai; James G Pipe; Hanzhang Lu
Journal:  Magn Reson Med       Date:  2018-01-25       Impact factor: 4.668

3.  Global fluctuations of cerebral blood flow indicate a global brain network independent of systemic factors.

Authors:  Li Zhao; David C Alsop; John A Detre; Weiying Dai
Journal:  J Cereb Blood Flow Metab       Date:  2017-08-17       Impact factor: 6.200

4.  Regional reproducibility of pulsed arterial spin labeling perfusion imaging at 3T.

Authors:  Yang Wang; Andrew J Saykin; Josef Pfeuffer; Chen Lin; Kristine M Mosier; Li Shen; Sungeun Kim; Gary D Hutchins
Journal:  Neuroimage       Date:  2010-08-25       Impact factor: 6.556

5.  Three-dimensional whole-brain perfusion quantification using pseudo-continuous arterial spin labeling MRI at multiple post-labeling delays: accounting for both arterial transit time and impulse response function.

Authors:  Qin Qin; Alan J Huang; Jun Hua; John E Desmond; Robert D Stevens; Peter C M van Zijl
Journal:  NMR Biomed       Date:  2013-10-16       Impact factor: 4.044

6.  Three-dimensional assessment of brain arterial compliance: Technical development, comparison with aortic pulse wave velocity, and age effect.

Authors:  Yang Li; Chantelle Lim; Michael Schär; Dengrong Jiang; Ye Qiao; Jay J Pillai; Hanzhang Lu
Journal:  Magn Reson Med       Date:  2021-05-12       Impact factor: 3.737

7.  Noninvasive assessment of arterial compliance of human cerebral arteries with short inversion time arterial spin labeling.

Authors:  Esther A H Warnert; Kevin Murphy; Judith E Hall; Richard G Wise
Journal:  J Cereb Blood Flow Metab       Date:  2014-12-17       Impact factor: 6.200

8.  Arterial Transit Time-corrected Renal Blood Flow Measurement with Pulsed Continuous Arterial Spin Labeling MR Imaging.

Authors:  Kazuhiro Shimizu; Nobuyuki Kosaka; Yasuhiro Fujiwara; Tsuyoshi Matsuda; Tatsuya Yamamoto; Tatsuro Tsuchida; Katsuki Tsuchiyama; Nobuyuki Oyama; Hirohiko Kimura
Journal:  Magn Reson Med Sci       Date:  2016-05-09       Impact factor: 2.471

9.  Arterial spin labeling characterization of cerebral perfusion during normal maturation from late childhood into adulthood: normal 'reference range' values and their use in clinical studies.

Authors:  Patrick W Hales; Jamie M Kawadler; Sarah E Aylett; Fenella J Kirkham; Christopher A Clark
Journal:  J Cereb Blood Flow Metab       Date:  2014-02-05       Impact factor: 6.200

10.  Three-dimensional echo-planar cine imaging of cerebral blood supply using arterial spin labeling.

Authors:  Manoj Shrestha; Toralf Mildner; Torsten Schlumm; Scott Haile Robertson; Harald Möller
Journal:  MAGMA       Date:  2016-05-25       Impact factor: 2.310

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.