Literature DB >> 17242243

Evaluation of aortocoronary bypass stents with cardiac MDCT compared with conventional catheter angiography.

Georg Mühlenbruch1, Andreas H Mahnken, Marco Das, Rüdiger Blindt, Christian Hohl, Joachim E Wildberger, Rolf W Günther, Harald P Kühl, Ralf Koos.   

Abstract

OBJECTIVE: The objective of our study was to determine the accuracy of 16-MDCT for evaluation of stent patency and in-stent stenosis in venous coronary bypass grafts. SUBJECTS AND METHODS: Fourteen patients who had previous stent placements in stenosed venous coronary bypass grafts underwent contrast-enhanced MDCT of the heart (collimation, 16 x 0.75 mm; 120 kV; 550 mAs(eff)) and invasive coronary angiography. A total of 20 stents were evaluated: Vessel and stent diameters proximal to, distal to, and at various sites inside the stent were measured on both techniques, and Bland-Altman plots and correlations were calculated. Image noise and image quality were also assessed applying a Student's t test for data comparison of image noise.
RESULTS: All 20 bypass stents were correctly classified as patent. Vessel diameters outside the stent showed an excellent correlation (r = 0.90) and in-stent diameters showed a good correlation (r = 0.72), with lower values for MDCT due to blooming artifacts. All significant in-stent stenoses were correctly classified.
CONCLUSION: In patients suspected of bypass in-stent stenosis, 16-MDCT may be considered as a valuable alternative to conventional angiography for evaluating bypass patency and in-stent stenosis.

Entities:  

Mesh:

Year:  2007        PMID: 17242243     DOI: 10.2214/AJR.06.0120

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  3 in total

1.  Assessment of in-stent restenosis using 64-MDCT: analysis of the CORE-64 Multicenter International Trial.

Authors:  Joanna J Wykrzykowska; Armin Arbab-Zadeh; Gustavo Godoy; Julie M Miller; Shezhang Lin; Andrea Vavere; Narinder Paul; Hiroyuki Niinuma; John Hoe; Jeffrey Brinker; Faisal Khosa; Sheryar Sarwar; Joao Lima; Melvin E Clouse
Journal:  AJR Am J Roentgenol       Date:  2010-01       Impact factor: 3.959

2.  CT Imaging of Coronary Stents: Past, Present, and Future.

Authors:  Andreas H Mahnken
Journal:  ISRN Cardiol       Date:  2012-09-11

3.  The measurement of opening angle and orifice area of a bileaflet mechanical valve using multidetector computed tomography.

Authors:  Dong-Hyeon Lee; Ho-Joong Youn; Sung-Bo Shim; Sun-Hee Lee; Jung-Im Jung; Seung-Eun Jung; Yun-Seok Choi; Chul-Soo Park; Yong-Seog Oh; Wook-Sung Chung; Jae-Hyung Kim
Journal:  Korean Circ J       Date:  2009-04-28       Impact factor: 3.243

  3 in total