Literature DB >> 17237643

Correlation between vortex ring formation and mitral annulus dynamics during ventricular rapid filling.

Arash Kheradvar1, Michele Milano, Morteza Gharib.   

Abstract

One of the most important fluid phenomena observed in the left ventricle during diastole is the presence of vortex rings that develop with a strong jet entering through the mitral valve. The present study is focused on the rapid filling phase of diastole, during which the left ventricle expands and receives blood through the fully open mitral valve. The atrioventricular system during the rapid filling phase was emulated experimentally with a simplified mechanical model in which the relevant pressure decay and the dimension of mitral annulus approximate the physiologic and pathologic values. Digital particle image velocimetry measurements were correlated with the force measurements on the mitral annulus plane to analyze the relation between flow and the mitral annulus motion. The recoil force on the displaced annulus plane was computed on the basis of plane acceleration and plane velocity and correlated with the inflow jet. Measurements of the recoil force for different values of the mitral annulus diameter showed that the recoil force was generated during fluid propulsion and that it is maximal for an annulus diameter close to the normal adult value in a healthy left ventricle. We also tested annulus diameters smaller and larger than the normal one. The smaller annulus corresponds to the stenotic valves and the larger annulus exists in dilated cardiomyopathy cases. In both conditions, the recoil force was found to be smaller than in the normal case. These observations are consistent with the previously reported results for dilated cardiomyopathy and mitral stenosis clinical conditions.

Entities:  

Mesh:

Year:  2007        PMID: 17237643     DOI: 10.1097/01.mat.0000249870.44625.22

Source DB:  PubMed          Journal:  ASAIO J        ISSN: 1058-2916            Impact factor:   2.872


  10 in total

Review 1.  Biomechanics.

Authors:  Masahiro Nishida
Journal:  J Artif Organs       Date:  2009-03-29       Impact factor: 1.731

2.  On the accuracy of intracardiac flow velocimetry methods.

Authors:  Arash Kheradvar
Journal:  J Echocardiogr       Date:  2017-02-15

3.  The Influence of Mitral Annuloplasty on Left Ventricular Flow Dynamics.

Authors:  Walter Rt Witschey; Donald Zhang; Francisco Contijoch; Jeremy R McGarvey; Madonna Lee; Satoshi Takebayashi; Chikashi Aoki; Yuchi Han; Joyce Han; Alex J Barker; James J Pilla; Robert C Gorman; Joseph H Gorman
Journal:  Ann Thorac Surg       Date:  2015-05-12       Impact factor: 4.330

4.  Left Ventricular Vortex Under Mitral Valve Edge-to-Edge Repair.

Authors:  Yingying Hu; Liang Shi; Siva Parameswaran; Sergey Smirnov; Zhaoming He
Journal:  Cardiovasc Eng Technol       Date:  2010-12       Impact factor: 2.495

5.  The relationship between systolic vector flow mapping parameters and left ventricular cardiac function in healthy dogs.

Authors:  Seijirow Goya; Tomoki Wada; Kazumi Shimada; Daiki Hirao; Ryou Tanaka
Journal:  Heart Vessels       Date:  2017-12-11       Impact factor: 2.037

6.  Alterations in Intracardiac Flow Patterns Affect Mitral Leaflets Dynamics in a Model of Ischemic Mitral Regurgitation.

Authors:  G Pilla; M Levack; J Mcgarvey; E Hwuang; G Zsido; J Gorman; J Pilla; W R Witschey; R Gorman
Journal:  Cardiovasc Eng Technol       Date:  2021-08-31       Impact factor: 2.495

7.  Vortices formed on the mitral valve tips aid normal left ventricular filling.

Authors:  John J Charonko; Rahul Kumar; Kelley Stewart; William C Little; Pavlos P Vlachos
Journal:  Ann Biomed Eng       Date:  2013-02-07       Impact factor: 3.934

8.  Recent advances in the application of computational mechanics to the diagnosis and treatment of cardiovascular disease.

Authors:  Juan C Del Alamo; Alison L Marsden; Juan C Lasheras
Journal:  Rev Esp Cardiol       Date:  2009-07       Impact factor: 4.753

9.  The vortex formation time to diastolic function relation: assessment of pseudonormalized versus normal filling.

Authors:  Erina Ghosh; Sándor J Kovács
Journal:  Physiol Rep       Date:  2013-11-26

10.  Conducting Polymeric Nanocomposites with a Three-Dimensional Co-flow Microfluidics Platform.

Authors:  Xiaodong Ma; Yuezhou Zhang; Korbinian Weisensee
Journal:  Micromachines (Basel)       Date:  2019-06-07       Impact factor: 2.891

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.