Dosimetric parameters as predictive factors for biochemical control in patients with higher risk prostate cancer treated with Pd-103 and supplemental beam radiation.

Peter Orio1, Kent Wallner, Gregory Merrick, Andrew Herstein, Paul Mitsuyama, Ken Thornton, Wayne Butler, Steven Sutlief.   

Abstract

PURPOSE: To analyze the role of dosimetric quality parameters in maximizing cancer eradication in higher risk prostate cancer patients treated with palladium (Pd)-103 and supplemental beam radiation.
METHODS: One-hundred-seventy-nine patients treated with Pd-103 and supplemental beam radiation, with minimum 2 years follow-up prostate-specific antigen (PSA) values and posttreatment computed tomography scans were analyzed. Dosimetric parameters included the V100 (percent of the postimplant volume covered by the prescription dose), the D90 (the minimum dose that covered 90% of the post implant volume), and the treatment margins (the radial distance between the prostatic edge and the prescription isodose). Treatment margins (TMs) were calculated using premarket software.
RESULTS: Freedom from biochemical failure was 79% at 3 years, with 92 of the 179 patients (51%) followed beyond 3 years. In comparing patients who did or did not achieve biochemical control, the most striking differences were in biologic factors of pretreatment PSA and Gleason score. The V100, D90, and average TM all showed nonsignificant trends to higher values in patients with biochemical control. In multivariate analysis of each of the three dosimetric parameters against PSA and Gleason score, TM showed the strongest correlation with biochemical control (p = 0.19).
CONCLUSIONS: For patients with intermediate and high-risk prostate cancer treated with Pd-103 brachytherapy and external beam radiation, biologic factors (PSA and Gleason score) were the most important determinants of cancer eradication. However, there is a trend to better outcomes among patients with higher quality implant parameters, suggesting that attention to implant quality will maximize the likelihood of cure.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17236959     DOI: 10.1016/j.ijrobp.2006.09.010

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  3 in total

1.  Permanent prostate brachytherapy postimplant magnetic resonance imaging dosimetry using positive contrast magnetic resonance imaging markers.

Authors:  Geoffrey V Martin; Thomas J Pugh; Usama Mahmood; Rajat J Kudchadker; Jihong Wang; Teresa L Bruno; Tharakeswara Bathala; Pierre Blanchard; Steven J Frank
Journal:  Brachytherapy       Date:  2017-05-10       Impact factor: 2.362

2.  Is it necessary to perform week three dosimetric analysis in low-dose-rate brachytherapy for prostate cancer when day 0 dosimetry is done? A quality assurance assessment.

Authors:  T Shaikh; N G Zaorsky; K Ruth; D Y Chen; R E Greenberg; J Li; K Crawford; E M Horwitz
Journal:  Brachytherapy       Date:  2014-11-07       Impact factor: 2.362

3.  Prostate deformation from inflatable rectal probe cover and dosimetric effects in prostate seed implant brachytherapy.

Authors:  Jun Lian; Yeqin Shao; Larry D Potter; Ronald C Chen; Jordan A Holmes; Eleanor A Pryser; Jie Shen; Dinggang Shen; Andrew Z Wang
Journal:  Med Phys       Date:  2016-12       Impact factor: 4.071

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.