Literature DB >> 17234998

Price of isotropy in multidetector CT.

Neal C Dalrymple1, Srinivasa R Prasad, Fadi M El-Merhi, Kedar N Chintapalli.   

Abstract

Recent advances in multidetector computed tomography (CT) have made isotropic data acquisition feasible for nearly every application. The benefits of routine use of isotropic data for image display and interpretation have been described in the literature and at educational conferences. However, there is usually a trade-off in the form of an increased radiation dose to the patient. The parameters that affect the radiation dose vary considerably in accordance with the CT scanner design, and those variations determine the cost in dose increase relative to the voxel size. The detector configuration and beam collimation (narrow or wide) used for a particular acquisition also affect the voxel size and the relationship between spatial resolution and the radiation dose. By closely comparing the quality of multidetector CT images obtained with different detector configurations on scanners with four, 16, 40, and 64 channels and the estimated radiation exposure incurred with each option, radiologists may achieve an understanding of the relationship between radiation dose and voxel size. This understanding, in turn, may help balance the need for diagnostic image quality against the concern for patient safety. Copyright RSNA, 2007.

Entities:  

Mesh:

Year:  2007        PMID: 17234998     DOI: 10.1148/rg.271065037

Source DB:  PubMed          Journal:  Radiographics        ISSN: 0271-5333            Impact factor:   5.333


  10 in total

Review 1.  Adult patient radiation doses from non-cardiac CT examinations: a review of published results.

Authors:  I Pantos; S Thalassinou; S Argentos; N L Kelekis; G Panayiotakis; E P Efstathopoulos
Journal:  Br J Radiol       Date:  2011-01-25       Impact factor: 3.039

2.  Utility of postmortem autopsy via whole-body imaging: initial observations comparing MDCT and 3.0 T MRI findings with autopsy findings.

Authors:  Jang Gyu Cha; Dong Hun Kim; Dae Ho Kim; Sang Hyun Paik; Jai Soung Park; Seong Jin Park; Hae Kyung Lee; Hyun Sook Hong; Duek Lin Choi; Kyung Moo Yang; Nak Eun Chung; Bong Woo Lee; Joong Seok Seo
Journal:  Korean J Radiol       Date:  2010-06-21       Impact factor: 3.500

3.  State-of-the-art CT and MR imaging and assessment of atherosclerotic carotid artery disease: standardization of scanning protocols and measurements-a consensus document by the European Society of Cardiovascular Radiology (ESCR).

Authors:  L Saba; C Loewe; T Weikert; M C Williams; N Galea; R P J Budde; R Vliegenthart; B K Velthuis; M Francone; J Bremerich; L Natale; K Nikolaou; J N Dacher; C Peebles; F Caobelli; A Redheuil; M Dewey; K F Kreitner; R Salgado
Journal:  Eur Radiol       Date:  2022-10-04       Impact factor: 7.034

4.  Pulmonary 64-MDCT angiography with 50 mL of iodinated contrast material in an unselected patient population: a feasible protocol.

Authors:  Henrique Simão Trad; Gustavo Santos Boasquevisque; Tiago Rangon Giacometti; Catherine Yang Trad; Orlando Salomão Zoghbi Neto; Clovis Simão Trad
Journal:  Radiol Bras       Date:  2016 Mar-Apr

5.  Enteral contrast in the computed tomography diagnosis of appendicitis: comparative effectiveness in a prospective surgical cohort.

Authors:  Frederick Thurston Drake; Rafael Alfonso; Puneet Bhargava; Carlos Cuevas; Manjiri K Dighe; Michael G Florence; Morris G Johnson; Gregory J Jurkovich; Scott R Steele; Rebecca Gaston Symons; Richard C Thirlby; David R Flum
Journal:  Ann Surg       Date:  2014-08       Impact factor: 12.969

6.  Computed Tomography (CT) Protocols Associated with Cardiac and Bone Single-Photon Emission Computed Tomography/CT (SPECT/CT) in Korea.

Authors:  Eun Jeong Lee; Ji Young Kim; Jung Mi Park; Bong-Il Song; Hongyoon Choi; Hye-Kyeong Shim; Hey Lim Park; Ho-Young Lee; Kyung Jae Lee; Joon-Kee Yoon; Seongho Seo; Seong Min Kim; Soo Bin Park; Young Seok Cho; Seong Hoon Kim
Journal:  Nucl Med Mol Imaging       Date:  2020-06-01

7.  A new 2D-3D registration gold-standard dataset for the hip joint based on uncertainty modeling.

Authors:  Fabio D'Isidoro; Christophe Chênes; Stephen J Ferguson; Jérôme Schmid
Journal:  Med Phys       Date:  2021-08-17       Impact factor: 4.506

8.  A case report of endorectal displacement of a right ureteral stent following radiochemotherapy and Bevacizumab.

Authors:  Alessio Tognarelli; Lorenzo Faggioni; Francesca Manassero; Angiolo Gadducci; Cesare Selli
Journal:  BMC Urol       Date:  2019-12-09       Impact factor: 2.264

9.  Unusual stent after ureteral substitution. A first case.

Authors:  Girolamo Fiorini; Giorgio Pomara; Francesca Manassero; Andrea Mogorovich; Lorenzo Faggioni; Cesare Selli
Journal:  BMC Urol       Date:  2012-11-29       Impact factor: 2.264

10.  CT-scan vs. 3D surface scanning of a skull: first considerations regarding reproducibility issues.

Authors:  Stella Fahrni; Lorenzo Campana; Alejandro Dominguez; Tanya Uldin; Fabrice Dedouit; Olivier Delémont; Silke Grabherr
Journal:  Forensic Sci Res       Date:  2017-06-13
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.