Literature DB >> 1723193

Catheter ablation of the atrioventricular junction using a helical microwave antenna: a novel means of coupling energy to the endocardium.

J J Langberg1, T Wonnell, M C Chin, W Finkbeiner, M Scheinman, P Stauffer.   

Abstract

Catheter ablation with either direct current defibrillator discharges or radiofrequency energy produces tissue injury via current flow from an electrode into the adjacent myocardium. In order to affect tissue at a distance, excessive power density may be produced at the electrode-tissue interface with the possibility of explosive gas formation or coagulum formation. A novel microwave catheter was developed with a helical antenna distally. This coil, although not in direct contact with the endocardium, radiates an electromagnetic field into the tissue that, in turn, causes thermal injury. The utility of this system for ablation was assessed in six dogs. The antenna catheter was introduced percutaneously and positioned so as to record the largest His electrogram. Microwave power (50 watts at 2,450 MHz) was applied for 114 +/- 118 seconds. Complete AV block was produced in all six animals with 1.8 +/- 1.2 applications. There was no ventricular ectopy or change in blood pressure during microwave ablation. One dog died 6 days after ablation. The remaining five dogs had persistent, complete AV block during 6 weeks of follow-up. Pathological analysis at 6 weeks revealed a large (mean 2.8 x 4.7 mm) fibrovascular scar in the region of the AV junction. Percutaneous microwave ablation of the endocardium appears feasible. By radiating an electromagnetic field without direct contact, this system can produce large lesions without being limited by desiccation of tissue and impedance rise.

Entities:  

Mesh:

Year:  1991        PMID: 1723193     DOI: 10.1111/j.1540-8159.1991.tb06481.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  3 in total

Review 1.  Alternate energy sources for catheter ablation.

Authors:  P J Wang; M K Homoud; M S Link; N A Estes III
Journal:  Curr Cardiol Rep       Date:  1999-07       Impact factor: 2.931

Review 2.  Antenna Designs for Microwave Tissue Ablation.

Authors:  Hojjatollah Fallahi; Punit Prakash
Journal:  Crit Rev Biomed Eng       Date:  2018

3.  Microwave catheter ablation of the atrioventricular junction in closed-chest dogs.

Authors:  J C Lin; R J Hariman; Y J Wang; Y G Wang
Journal:  Med Biol Eng Comput       Date:  1996-07       Impact factor: 2.602

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.