Literature DB >> 17228574

Reliability of conformational measurements in the horse using a three-dimensional motion analysis system.

R Weller1, T Pfau, D Babbage, E Brittin, S A May, A M Wilson.   

Abstract

REASONS FOR PERFORMING STUDY: The importance of a reliable method for conformation studies is generally acknowledged, but there are only limited data on the accuracy and precision of current assessment methods.
OBJECTIVES: To assess (1) the accuracy and repeatability of marker placement, (2) influence of stance of the horse on conformational parameters, (3) practicality of a computerised motion analysis system and (4) to compare the computerised motion analysis system to photographic systems of assessment.
METHODS: Twenty-eight reflective markers placed over anatomical landmarks were located in 3D using a computerised motion analysis system and their coordinates used to calculate segment lengths and joint angles. Four experiments, involving a cadaver study, a series of repeated measures on a single Thoroughbred and repeat measurements on 108 racehorses were performed.
RESULTS: Identification of anatomical landmarks was found to introduce the biggest variation in the measurements for proximal conformation parameters with the interoperator being larger than intraoperator variation. Length measurements were least influenced by stance, with distal interphalangeal and metacarpo/metatarsophalangeal joint angles being the most variable. In some measurements, the variation between stances within a horse proved to be almost as large as between horses, rendering these parameters less useful as predictors of performance or orthopaedic health.
CONCLUSIONS: A computerised motion analysis system allows 3D assessment of conformation with high accuracy and precision. It eliminates 3 major sources of error associated with photography-based methods and increases accuracy of conformational assessment by allowing repeat measurements in a relatively short period. POTENTIAL RELEVANCE: Studies on conformation should be viewed in the light of the limitations of the measurement technique used. The presented method maximises accuracy and precision and is a valuable basis for future studies investigating the effect of conformation on performance or orthopaedic health.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17228574     DOI: 10.2746/042516406x150367

Source DB:  PubMed          Journal:  Equine Vet J        ISSN: 0425-1644            Impact factor:   2.888


  4 in total

1.  2D versus 3D in the kinematic analysis of the horse at the trot.

Authors:  F Miró; R Santos; J L Garrido-Castro; A M Galisteo; R Medina-Carnicer
Journal:  Vet Res Commun       Date:  2008-12-11       Impact factor: 2.459

2.  Horse phenotyping based on video image analysis of jumping performance for conservation breeding.

Authors:  Dorota Lewczuk; Ewa Metera-Zarzycka
Journal:  PeerJ       Date:  2019-08-09       Impact factor: 2.984

3.  Estimates of Genetic Parameters for Shape Space Data in Franches-Montagnes Horses.

Authors:  Annik Imogen Gmel; Alexander Burren; Markus Neuditschko
Journal:  Animals (Basel)       Date:  2022-08-25       Impact factor: 3.231

4.  Repeatability, reproducibility and consistency of horse shape data and its association with linearly described conformation traits in Franches-Montagnes stallions.

Authors:  Annik Imogen Gmel; Thomas Druml; Katrin Portele; Rudolf von Niederhäusern; Markus Neuditschko
Journal:  PLoS One       Date:  2018-08-27       Impact factor: 3.240

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.