A microscale device for measuring emissions from materials for indoor use.

T Schripp1, B Nachtwey, J Toelke, T Salthammer, E Uhde, M Wensing, M Bahadir.   

Abstract

Emission test chambers or cells are used to determine organic vapour emissions from construction products under controlled conditions. Polymeric car trim component emissions are typically evaluated using direct thermal desorption/extraction. The Microchamber/Thermal Extractor (mu-CTE, Markes International) was developed to provide both a complementary tool for rapid screening of volatile organic compound (VOC) emissions--suitable for industrial quality control--and a means for thermal extraction of larger, more representative samples of car trim components. To determine the degree of correlation between conventional emission test methods and the microchamber, experiments were carried out under different conditions of temperature, air change rate and sample conditioning time. Good quantitative and qualitative correlation was obtained for measurements at ambient temperature. Moreover, it was shown that ambient-temperature emissions data collected using the mu-CTE as rapidly as possible--i.e. with minimal or no sample conditioning time--nevertheless provided a reliable guide as to how well that material would perform in subsequent 3-day chamber tests of VOC emissions. The parameters found to have the greatest influence on data correlation for experiments carried out at elevated temperatures were the sample mass (for bulk emissions testing) and the conditioning time. The results also showed that, within the constraints of inherent sample homogeneity, the mu-CTE gave reproducible emissions data, despite its small sample size/capacity relative to that of conventional chambers. Preliminary results of modelling the air flow within a microchamber using computational fluid dynamics showed a high degree of turbulent flow and two potential areas of still air which could cause sink effects. However, the experimental data reported here and in previous studies showed enhanced recovery of semivolatile components from the mu-CTE relative to a recovery from a 1 m(3) conventional chamber. This indicates that if these areas of relatively still air are present within the microchamber, they do not appear to be significant in practice.

Entities:  

Year:  2007        PMID: 17225110     DOI: 10.1007/s00216-006-1057-2

Source DB:  PubMed          Journal:  Anal Bioanal Chem        ISSN: 1618-2642            Impact factor:   4.142


  6 in total

1.  Measurements of chlorinated volatile organic compounds emitted from office printers and photocopiers.

Authors:  Joanna Kowalska; Małgorzata Szewczyńska; Małgorzata Pośniak
Journal:  Environ Sci Pollut Res Int       Date:  2014-10-18       Impact factor: 4.223

2.  POM/EVA Blends with Future Utility in Fused Deposition Modeling.

Authors:  Mateusz Galeja; Klaudiusz Wypiór; Jan Wachowicz; Przemysław Kędzierski; Aleksander Hejna; Mariusz Marć; Krzysztof Klewicz; Jadwiga Gabor; Hubert Okła; Andrzej Szymon Swinarew
Journal:  Materials (Basel)       Date:  2020-06-29       Impact factor: 3.623

3.  Emissions of DEHP-free PVC flooring.

Authors:  Emmanuelle Castagnoli; Peter Backlund; Oskari Talvitie; Tapani Tuomi; Arja Valtanen; Raimo Mikkola; Hanna Hovi; Katri Leino; Jarek Kurnitski; Heidi Salonen
Journal:  Indoor Air       Date:  2019-09-11       Impact factor: 5.770

4.  Formaldehyde Emissions from Wooden Toys: Comparison of Different Measurement Methods and Assessment of Exposure.

Authors:  Morgane Even; Olaf Wilke; Sabine Kalus; Petra Schultes; Christoph Hutzler; Andreas Luch
Journal:  Materials (Basel)       Date:  2021-01-07       Impact factor: 3.623

5.  Ground Tire Rubber Modified by Elastomers via Low-Temperature Extrusion Process: Physico-Mechanical Properties and Volatile Organic Emission Assessment.

Authors:  Paulina Wiśniewska; Łukasz Zedler; Mariusz Marć; Marek Klein; Józef Haponiuk; Krzysztof Formela
Journal:  Polymers (Basel)       Date:  2022-01-28       Impact factor: 4.329

6.  Micro-Chamber/Thermal Extractor (µ-CTE) as a new sampling system for VOCs emitted by feces.

Authors:  Ileana Andreea Ratiu; Radik Mametov; Tomasz Ligor; Bogusław Buszewski
Journal:  Sci Rep       Date:  2021-09-21       Impact factor: 4.379

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.