Literature DB >> 17224756

Clinical evaluation of applanation resonance tonometry: a comparison with Goldmann applanation tonometry.

Per Hallberg1, Anders Eklund, Tomas Bäcklund, Christina Lindén.   

Abstract

PURPOSE: The purpose of this study was to calibrate and evaluate the precision of the new applanation resonance tonometry (ART) in a clinical study designed in accordance with the International Standard Organization's requirements.
METHODS: This was a prospective, randomized, single-center study, where healthy volunteers and patients participated. A total of 153 eyes were divided into 3 groups with respect to their intraocular pressure (IOP) at screening: <16 mm Hg, 16 to 23 mm Hg, and >23 mm Hg. IOP was measured with Goldmann applanation tonometry (GAT) as reference method and by ART in both a biomicroscope (ARTBiom) and a handheld (ARTHand) setup with a 10-minutes pause between methods. The mean of 6 readings was regarded as one measurement value.
RESULTS: Mean age of the subjects was 59 years (range 20 to 87 y). GAT showed a mean IOP of 20.0 mm Hg (range 8.5 to 43.5 mm Hg, n=153). The precision was 2.07 mm Hg for ARTBiom and 2.50 mm Hg for ARTHand, with a significant dependency for age as compared with GAT. Measurement order produced a decreasing IOP with a mean of 2.3 mm Hg between the first and last method.
CONCLUSIONS: The precision obtained in both ARTBiom and ARTHand was within the limits set by the International Standard Organization standards for tonometers. The standardized procedure and the stability of the biomicroscope setup resulted in a slightly better precision as compared with the handheld setup. Despite a 10-minutes pause between measurements, the order was a significant factor, possibly because the patients were more apprehensive at the first measurement.

Entities:  

Mesh:

Year:  2007        PMID: 17224756     DOI: 10.1097/01.ijg.0000243468.28590.8e

Source DB:  PubMed          Journal:  J Glaucoma        ISSN: 1057-0829            Impact factor:   2.503


  3 in total

1.  Age-dependency of ocular parameters: a cross sectional study of young and elderly healthy subjects.

Authors:  G Jóhannesson; P Hallberg; K Ambarki; A Eklund; C Lindén
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2015-08-13       Impact factor: 3.117

2.  Can we trust intraocular pressure measurements in eyes with intracameral air?

Authors:  Gauti Jóhannesson; Christina Lindén; Anders Eklund; Anders Behndig; Per Hallberg
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2014-07-17       Impact factor: 3.117

3.  Repeatability and reproducibility of applanation resonance tonometry: a cross-sectional study.

Authors:  Laura Ottobelli; Paolo Fogagnolo; Paolo Frezzotti; Stefano De Cillà; Elena Vallenzasca; Maurizio Digiuni; Ruggiero Paderni; Ilaria Motolese; Simone Alex Bagaglia; Eduardo Motolese; Luca Rossetti
Journal:  BMC Ophthalmol       Date:  2015-04-10       Impact factor: 2.209

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.