Literature DB >> 17224119

Efficacy of different intraocular lens materials and optic edge designs in preventing posterior capsular opacification: a meta-analysis.

Jin-Wei Cheng1, Rui-Li Wei, Ji-Ping Cai, Gui-Lin Xi, Huang Zhu, You Li, Xiao-Ye Ma.   

Abstract

PURPOSE: To evaluate the efficacy of different intraocular lens (IOL) materials and optic edge designs in preventing posterior capsular opacification (PCO).
DESIGN: Systematic review and meta-analysis.
METHODS: Pertinent studies were selected through an electronic search of the Cochrane Library, MEDLINE, and Embase. The randomized controlled trials meeting the predefined criteria were reviewed systematically by meta-analysis. The treatment effects were measured as risk difference, and the pooled estimates were computed according to a random effect model.
RESULTS: In total, 23 randomized controlled trials were included in the present meta-analysis. The pooled risk differences of Nd:YAG laser capsulotomy rates were -24% (95% confidence interval [CI], -29% to -20%) comparing acrylic with polymethylmethacrylate (PMMA) lenses; -9% (95% CI, -17% to -1%) comparing silicone with PMMA lenses; 14% (95% CI, -8% to 36%) comparing hydrogel with PMMA lenses; 4% (95% CI, -2% to 10%) comparing silicone with acrylic lenses; 19% (95% CI, 8% to 30%) comparing hydrogel with acrylic lenses; and 28% (95% CI, 10% to 46%) comparing hydrogel with silicone lenses. The pooled risk differences of PCO rates were -39% (95% CI, -47% to -31%) comparing acrylic with PMMA lenses; -14% (95% CI, -29% to 0%) comparing silicone with acrylic lenses; 56% (95% CI, 36% to 75%) comparing hydrogel with acrylic lenses; and 48% (95% CI, 31% to 64%) comparing hydrogel with silicone lenses. When comparing sharp with rounded-edge designs, pooled risk differences of capsulotomy rates were -47% (95% CI, -77% to -17%) in PMMA lenses, -22% (95% CI, -47% to 2%) in acrylic lenses, and -9% (95% CI, -17% to 0%) in silicone lenses; pooled risk differences of PCO rates were -28% (95% CI, -50% to -7%) in acrylic lenses and -37% (95% CI, -46% to -27%) in silicone lenses.
CONCLUSIONS: The rates of PCO and Nd:YAG laser capsulotomy may be influenced by different IOL biomaterials and optic edge designs. The lenses made by acrylic and silicone and those with sharp optic edges are superior in lowering the rates of PCO and laser capsulotomy.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17224119     DOI: 10.1016/j.ajo.2006.11.045

Source DB:  PubMed          Journal:  Am J Ophthalmol        ISSN: 0002-9394            Impact factor:   5.258


  33 in total

1.  [Secondary increase in intraocular pressure after complication-free cataract operation with implantation of the posterior chamber lens].

Authors:  D Kook; T Kohnen
Journal:  Ophthalmologe       Date:  2009-02       Impact factor: 1.059

2.  [Aberration corrected intraocular lens for microincision cataract surgery (MICS). Intraindividual comparison with a conventional lens - 1-year follow-up].

Authors:  M Möglich; H Häberle; D T Pham; C Wirbelauer
Journal:  Ophthalmologe       Date:  2009-10       Impact factor: 1.059

Review 3.  Hydroxyethyl starch for cardiovascular surgery: a systematic review of randomized controlled trials.

Authors:  Xue-Yin Shi; Zui Zou; Xing-Ying He; Hai-Tao Xu; Hong-Bin Yuan; Hu Liu
Journal:  Eur J Clin Pharmacol       Date:  2011-03-02       Impact factor: 2.953

4.  Identification and Description of Reliable Evidence for 2016 American Academy of Ophthalmology Preferred Practice Pattern Guidelines for Cataract in the Adult Eye.

Authors:  Asieh Golozar; Yujiang Chen; Kristina Lindsley; Benjamin Rouse; David C Musch; Flora Lum; Barbara S Hawkins; Tianjing Li
Journal:  JAMA Ophthalmol       Date:  2018-05-01       Impact factor: 7.389

5.  Effect of delivery of MMP inhibitors from PDMS as a model IOL material on PCO markers.

Authors:  Diana Morarescu; Judy A West-Mays; Heather D Sheardown
Journal:  Biomaterials       Date:  2009-12-22       Impact factor: 12.479

6.  Anterior segment complications after phacoemu-lsification combined vitrectomy and foldable intraocular lens implantation.

Authors:  Qin-Xiang Zheng; Rong-Han Wu; Yuan-Ping Zhang; Ming Xu; Wen-Sheng Li
Journal:  Int J Ophthalmol       Date:  2010-09-18       Impact factor: 1.779

7.  Foldable vs rigid lenses after phacoemulsification for cataract surgery: a randomised controlled trial.

Authors:  A Hennig; L R Puri; H Sharma; J R Evans; D Yorston
Journal:  Eye (Lond)       Date:  2014-02-21       Impact factor: 3.775

8.  Intraocular lenses for the treatment of age-related cataracts: an evidence-based analysis.

Authors: 
Journal:  Ont Health Technol Assess Ser       Date:  2009-10-01

9.  Manual small incision cataract surgery in a United Kingdom university teaching hospital setting.

Authors:  Ghee Soon Ang; Samantha Wheelan; Frank D Green
Journal:  Int Ophthalmol       Date:  2009-01-08       Impact factor: 2.031

10.  Changing incidence of lens extraction over 20 years: the Beaver Dam eye study.

Authors:  Barbara E K Klein; Kerri P Howard; Kristine E Lee; Ronald Klein
Journal:  Ophthalmology       Date:  2013-08-08       Impact factor: 12.079

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.