Literature DB >> 17224021

Influence of cyclosporin A on quality of bone around integrated dental implants: a radiographic study in rabbits.

Celso Eduardo Sakakura1, Elcio Marcantonio, Ann Wenzel, Gulnara Scaf.   

Abstract

OBJECTIVES: To evaluate the influence of cyclosporin A (CsA) administration on bone around integrated dental implants assessed by a bone quality index and by quantitative subtraction radiography.
MATERIAL AND METHODS: A total of 36 machine surface commercial implants were placed in 18 adult rabbits. After a 3-month healing period without any disturbance, the animals were randomly divided into three groups of six animals each. Group A was sacrificed at this time. CsA was injected subcutaneously in an immunosuppressive dose of 10 mg/kg/day in a test group (Group T), and a Group B served as a control, receiving only vehicle. After 3 months of cyclosporin administration, the animals of both Groups B and T were sacrificed. Radiographs were obtained at implant surgery and at the day of sacrifice with a CMOS sensor. Bone quality around the implants was compared between the groups using a bone quality index and quantitative subtraction radiography.
RESULTS: The bone analysis showed that in Group T, the bone quality changed dramatically from a dense cortical to a loose trabecular bone structure (P<0.0001, chi(2) test) while in Groups A and B there were no significant differences. Quantitative digital subtraction radiography showed significantly (P<0.05) lower gray shade values (radiographic density) in a region of bone formation around the implants in Group T (118+/-12) than in Groups A (161+/-6) and B (186+/-10).
CONCLUSION: Within the limits of this study, CsA administration has a negative effect on the quality of bone around integrated dental implant.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17224021     DOI: 10.1111/j.1600-0501.2006.01253.x

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  3 in total

Review 1.  Dental implants in patients affected by systemic diseases.

Authors:  N Donos; E Calciolari
Journal:  Br Dent J       Date:  2014-10       Impact factor: 1.626

2.  No deleterious effect of low dose methotrexate on titanium implant osseointegration in a rabbit model.

Authors:  Janaina Badin Carvas; Rosa Maria Rodrigues Pereira; Eloisa Bonfá; Celey Aparecida Silveira; Luiz Lapa Lima; Valéria de Falco Caparbo; Suzana Beatriz Veríssimo de Mello
Journal:  Clinics (Sao Paulo)       Date:  2011       Impact factor: 2.365

3.  Evaluation of Effect of Low-Dose Methotrexate on Osseointegration of Implants: A Biomechanical Study on Dogs.

Authors:  Mohamad Tavakoli; Jaber Yaghini; Ahmad Moghare Abed; Meisam Malekzadeh; Dina Maleki
Journal:  Open Dent J       Date:  2018-07-31
  3 in total