Literature DB >> 17223031

Microbial fuel cell-based biosensor for fast analysis of biodegradable organic matter.

Ampai Kumlanghan1, Jing Liu, Panote Thavarungkul, Proespichaya Kanatharana, Bo Mattiasson.   

Abstract

The current study was made to develop a biosensor based on a single-chamber microbial fuel cell in which anaerobes were retained in the anode compartment separated from the cathode compartment by a proton exchange membrane. In the sensor a replaceable anaerobic consortium was used for analyzing biodegradable organic matter. The anaerobes acted as biocatalysts in oxidizing organic matter and transferring electrons to the anode. The biocatalysts were renewed for each sample analysis by replacing the old anaerobic consortium with an equal amount of fresh one. A glucose standard solution was used as the target substrate. To obtain the maximum sensor output, the MFC-based sensor system was optimized using an 800 Omega resistor as the load to the external electric circuit and 25 mM phosphate buffer with 50mM NaCl as catholyte in the aerobic compartment. The temperature of anaerobic compartment was maintained at optimal 37 degrees C. The cell potential across the electrodes increased with increasing loading of glucose. The sensor response was linear against concentration of glucose up to 25 gl(-1). The detection limit was found as 0.025 gl(-1). The microbial fuel cell with replaceable anaerobic consortium could be used as a biosensor for on-line monitoring of organic matter.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17223031     DOI: 10.1016/j.bios.2006.12.014

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  9 in total

1.  Toxicity assessment of copper by electrochemically active bacteria in wastewater.

Authors:  Lijuan Zhang; Sam Fong Yau Li; Huchun Tao
Journal:  Environ Geochem Health       Date:  2018-04-09       Impact factor: 4.609

2.  Effects of Operating Parameters on Measurements of Biochemical Oxygen Demand Using a Mediatorless Microbial Fuel Cell Biosensor.

Authors:  Min-Chi Hsieh; Chiu-Yu Cheng; Man-Hai Liu; Ying-Chien Chung
Journal:  Sensors (Basel)       Date:  2015-12-28       Impact factor: 3.576

3.  A Terrestrial Single Chamber Microbial Fuel Cell-based Biosensor for Biochemical Oxygen Demand of Synthetic Rice Washed Wastewater.

Authors:  Washington Logroño; Alex Guambo; Mario Pérez; Abudukeremu Kadier; Celso Recalde
Journal:  Sensors (Basel)       Date:  2016-01-15       Impact factor: 3.576

4.  Development and Long-Term Stability of a Novel Microbial Fuel Cell BOD Sensor with MnO₂ Catalyst.

Authors:  Shailesh Kharkwal; Yi Chao Tan; Min Lu; How Yong Ng
Journal:  Int J Mol Sci       Date:  2017-01-28       Impact factor: 5.923

5.  Towards implementation of cellular automata in Microbial Fuel Cells.

Authors:  Michail-Antisthenis I Tsompanas; Andrew Adamatzky; Georgios Ch Sirakoulis; John Greenman; Ioannis Ieropoulos
Journal:  PLoS One       Date:  2017-05-12       Impact factor: 3.240

Review 6.  Microbial Fuels Cell-Based Biosensor for Toxicity Detection: A Review.

Authors:  Tuoyu Zhou; Huawen Han; Pu Liu; Jian Xiong; Fake Tian; Xiangkai Li
Journal:  Sensors (Basel)       Date:  2017-09-28       Impact factor: 3.576

7.  Customizable design strategies for high-performance bioanodes in bioelectrochemical systems.

Authors:  Yu-Ting He; Qian Fu; Yuan Pang; Qing Li; Jun Li; Xun Zhu; Ren-Hao Lu; Wei Sun; Qiang Liao; Uwe Schröder
Journal:  iScience       Date:  2021-02-10

8.  Real-time monitoring of subsurface microbial metabolism with graphite electrodes.

Authors:  Colin Wardman; Kelly P Nevin; Derek R Lovley
Journal:  Front Microbiol       Date:  2014-11-21       Impact factor: 5.640

9.  Methane Emission in a Specific Riparian-Zone Sediment Decreased with Bioelectrochemical Manipulation and Corresponded to the Microbial Community Dynamics.

Authors:  Elliot S Friedman; Lauren E McPhillips; Jeffrey J Werner; Angela C Poole; Ruth E Ley; M Todd Walter; Largus T Angenent
Journal:  Front Microbiol       Date:  2016-01-11       Impact factor: 5.640

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.