Literature DB >> 17222021

Gradient elution moving boundary electrophoresis for high-throughput multiplexed microfluidic devices.

Jonathan G Shackman1, Matthew S Munson, David Ross.   

Abstract

A novel method for performing electrophoretic separations is described-gradient elution moving boundary electrophoresis (GEMBE). The technique utilizes the electrophoretic migration of chemical species in combination with variable hydrodynamic bulk counterflow of the solution through a separation capillary or microfluidic channel. Continuous sample introduction is used, eliminating the need for a sample injection mechanism. Only analytes with an electrophoretic velocity greater than the counterflow velocity enter the separation channel. The counterflow velocity is varied over time so that each analyte is brought into the separation column at different times, allowing for high-resolution separations in very short channels. The new variable of bulk flow acceleration affords a new selectivity parameter to electrophoresis analogous to gradient elution compositions in chromatography. Because it does not require extra channels or access ports to form an injection zone and because separations can be performed in very short channels, GEMBE separations can be implemented in much smaller areas on a micro-fluidic chip as compared to conventional capillary electrophoresis. Demonstrations of GEMBE separations of small dye molecules, amino acids, DNA, and immunoassay products are presented. A low-cost, polymeric, eight-channel multiplexed microfluidic device was fabricated to demonstrate the reduced area requirements of GEMBE; the device was less than 1 in.2 in area and required only n + 1 fluidic access ports per n analyses (in this instance, nine ports for eight analyses). Parallel separations of fluorescein and carboxyfluorescein yielded less than 3% relative standard deviation (RSD) in interchannel migration times and less than 5% RSD in both peak and height measurements. The device was also used to generate a calibration curve for a homogeneous insulin immunoassay using each of the eight channels as a calibration point with less than 5% RSD at each point with replicate analyses.

Entities:  

Year:  2007        PMID: 17222021     DOI: 10.1021/ac061759h

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  6 in total

1.  Quantitative assessment of flow and electric fields for electrophoretic focusing at a converging channel entrance with interfacial electrode.

Authors:  Michael W Keebaugh; Prasun Mahanti; Mark A Hayes
Journal:  Electrophoresis       Date:  2012-07       Impact factor: 3.535

2.  Separation and Detection of Trace Fentanyl from Complex Mixtures Using Gradient Elution Moving Boundary Electrophoresis.

Authors:  Shannon T Krauss; David Ross; Thomas P Forbes
Journal:  Anal Chem       Date:  2019-09-27       Impact factor: 6.986

Review 3.  Multiplexed detection and applications for separations on parallel microchips.

Authors:  John F Dishinger; Robert T Kennedy
Journal:  Electrophoresis       Date:  2008-08       Impact factor: 3.535

4.  Development of the resolution theory for electrophoretic exclusion.

Authors:  Stacy M Kenyon; Michael W Keebaugh; Mark A Hayes
Journal:  Electrophoresis       Date:  2014-07-21       Impact factor: 3.535

5.  Using electrophoretic exclusion to manipulate small molecules and particles on a microdevice.

Authors:  Stacy M Kenyon; Noah G Weiss; Mark A Hayes
Journal:  Electrophoresis       Date:  2012-04       Impact factor: 3.535

6.  Macrocycle peptides delineate locked-open inhibition mechanism for microorganism phosphoglycerate mutases.

Authors:  Hao Yu; Patricia Dranchak; Zhiru Li; Ryan MacArthur; Matthew S Munson; Nurjahan Mehzabeen; Nathan J Baird; Kevin P Battalie; David Ross; Scott Lovell; Clotilde K S Carlow; Hiroaki Suga; James Inglese
Journal:  Nat Commun       Date:  2017-04-03       Impact factor: 14.919

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.