Literature DB >> 17219987

Real-time three-dimensional echocardiography in assessment of congenital double orifice mitral valve.

Qing Lu1, Xiaofang Lu, Mingxing Xie, Xinfang Wang, Jing Wang, Yali Yang, Li Yuan, Lin He, Xiatian Liu, Manli Fu.   

Abstract

The application of real-time three-dimensional echocardiography (RT 3DE) in the diagnosis of double orifice mitral valve (DOMV) was explored. Five cases of DOMV were examined by using 2-dimensional echocardiography (2DE) and RT 3DE. The spatial morphology of malformed mitral valve and its change in hemodynamics were observed. DOMV associated with partial atrioventricular septal defect was found in 3 cases (in which 2 cases had cleft mitral valve) and isolated DOMV in 2 cases; and moderate to severe mitral regurgitation was detected in 3 cases, and mild mitral regurgitation in 1, and no regurgitation in 1 case; 1 case had complicated rhumatic heart disease. Three cases were preoperatively discovered by 2DE, while 2 missed (1 case was discovered postoperatively). Four cases were diagnosed by RT 3DE preoperatively, and 1 case was diagnosed postoperatively (not examined by RT 3DE preoperatively). It was suggested that RT 3DE is a reliable technique in the diagnosis of DOMV; it permitted comprehensive and noninvasive assessment of mitral valve and may supplement 2D TTE in the assessment of DOMV.

Entities:  

Mesh:

Year:  2006        PMID: 17219987     DOI: 10.1007/s11596-006-0539-y

Source DB:  PubMed          Journal:  J Huazhong Univ Sci Technolog Med Sci        ISSN: 1672-0733


  2 in total

1.  Double orifice mitral valve: a case report and review of management.

Authors:  A A Majid
Journal:  J Cardiovasc Surg (Torino)       Date:  1991 Nov-Dec       Impact factor: 1.888

2.  The tensor apparatus in double-orifice mitral valve: interpretation of echocardiographic findings.

Authors:  N Ciampani; D Vecchiola; C Silenzi; C Costantini; M Mazzanti; G Iacobone; A Purcaro
Journal:  J Am Soc Echocardiogr       Date:  1997-10       Impact factor: 5.251

  2 in total
  3 in total

1.  Dynamic characteristic mechanism of atrial septal defect using real-time three-dimensional echocardiography and evaluation of right ventricular functions.

Authors:  Gao-Wa Sharen; Jun Zhang; Chuan Qin; Qing Lv
Journal:  J Huazhong Univ Sci Technolog Med Sci       Date:  2017-02-22

2.  Three dimensional echocardiography in congenital heart defects.

Authors:  Girish S Shirali
Journal:  Ann Pediatr Cardiol       Date:  2008-01

3.  A rare case of double orifice mitral valve with perimembranous ventricular septal defect: Application of three-dimensional echocardiography for clinical decision making.

Authors:  Rohit Tandon; Shibba Takkar; Shailender Kumbhkarni; Naveen Kumar; Naved Aslam; Bishav Mohan; G S Wander
Journal:  Ann Pediatr Cardiol       Date:  2010-01
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.