Literature DB >> 17214624

Myocardial tissue velocities in neonates.

Filiz Ekici1, Semra Atalay, Nazire Ozcelik, Tayfun Uçar, Erdal Yilmaz, Ercan Tutar.   

Abstract

BACKGROUND: Tissue Doppler echocardiography (TDE) has been applied to the children age group; however, myocardial tissue velocities of neonates have been reported by few researchers.
METHODS: Myocardial velocities along the longitudinal axis of the left ventricle were measured in two groups: 50 term neonates within 5 days after birth and 54 healthy children by TDE. Sample volumes were placed in mitral lateral annulus (MLA), mitral medial annulus (MMA), and in the basal and middle parts of the left ventricular lateral wall (LVLW) and interventricular septum (IVS).
RESULTS: The highest myocardial velocities were obtained from MLA. In all segments, the mean systolic velocity (Sw) was found significantly lower than the mean early diastolic (Ew) and atrial systolic velocities (Aw) (P < 0.0001). The mean Aw was the dominant component in the MMA and were significantly higher than Ew (P < 0.001). The mean Ew/Aw in the MMA and MLA increased significantly while replacing the Doppler beam from base to apex. TDE indexes of neonates, except Aw obtained from MLA and MMA, were significantly lower than that of children group (P < 0.0001 and P < 0.0001, respectively). The mean E/Ew ratio of the left ventricle in neonates was found to be significantly higher than that found in children group (P < 0.0001).
CONCLUSION: In neonates, the diastolic and systolic myocardial velocities of the left ventricle were significantly lower than those measured in the children group. Decreased myocardial tissue values of neonates might be reflecting the immaturity of neonatal myocardium.

Entities:  

Mesh:

Year:  2007        PMID: 17214624     DOI: 10.1111/j.1540-8175.2006.00351.x

Source DB:  PubMed          Journal:  Echocardiography        ISSN: 0742-2822            Impact factor:   1.724


  4 in total

1.  Ejection time-corrected systolic velocity improves accuracy in the evaluation of myocardial dysfunction: a study in piglets.

Authors:  Hans Henrik Odland; Grete Anette Birkeland Kro; Berit H Munkeby; Thor Edvardsen; Ola Didrik Saugstad; Erik Thaulow
Journal:  Pediatr Cardiol       Date:  2010-08-19       Impact factor: 1.655

2.  Changes in Myocardial Contractility and Electromechanical Interval During the First Month of Life in Healthy Neonates.

Authors:  Peter C Kahr; Maike K Kahr; Himanshu Dabral; Ramesh Agarwal; Shyam S Kothari; Anita Saxena; Sivasubramanian Ramakrishnan
Journal:  Pediatr Cardiol       Date:  2015-10-24       Impact factor: 1.655

3.  Serial assessment of left-ventricular function using tissue Doppler imaging in premature infants within 7 days of life.

Authors:  Masanori Murase; Takeshi Morisawa; Akihito Ishida
Journal:  Pediatr Cardiol       Date:  2013-03-09       Impact factor: 1.655

Review 4.  Tissue Doppler velocity imaging and event timings in neonates: a guide to image acquisition, measurement, interpretation, and reference values.

Authors:  Eirik Nestaas; Ulf Schubert; Willem P de Boode; Afif El-Khuffash
Journal:  Pediatr Res       Date:  2018-07       Impact factor: 3.756

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.