Chaitanya S Mudgal1, David Ring.
Abstract
Combined injuries of the distal radius and shaft are rare, are usually caused by high energy, and pose a surgical dilemma. Surgical tactics and implants that are routinely used either for isolated fractures of the distal radius or for fractures of the radial shaft are often not applicable for this combined injury. We describe a technique of dual-stacked plating for these metadiaphyseal fractures and its use in two patients.Entities:
Mesh:
Year: 2007 PMID: 17211272 DOI: 10.1097/01.bot.0000245682.07078.89
Source DB: PubMed Journal: J Orthop Trauma ISSN: 0890-5339 Impact factor: 2.512