Literature DB >> 17211167

Iatrogenic pulmonary artery rupture.

Jean S Bussières1.   

Abstract

PURPOSE OF REVIEW: Pulmonary artery rupture is probably the most devastating complication associated with the use of the pulmonary artery catheter. This rare but disastrous situation requires a clear intervention plan. RECENT
FINDINGS: The initial presentation of pulmonary artery ruptures may be as obvious as a massive pulmonary hemorrhage or as subtle as a cough associated with minimal hemoptysis, or it may even be totally asymptomatic. A patient presenting any clinical manifestation of pulmonary artery rupture may develop a pulmonary artery false aneurysm, which is the accumulation of blood in an aneurismal sac compressed by lung parenchyma. This condition requires intervention because delayed hemorrhage may occur and recurrence can be massive and fatal. Following an initial episode of suspected pulmonary artery rupture, the patient should undergo immediate radiological investigation. If a diagnosis of pulmonary artery false aneurysm is confirmed, selective angiographic embolization helps reduce morbidity and mortality.
SUMMARY: The incidence of pulmonary artery ruptures is probably underestimated because many hemoptysis episodes or radiological infiltrations associated with pulmonary artery catheter use are not investigated. Also, the natural evolution of the pulmonary artery false aneurysm is unknown. The incidence of spontaneous healing, bleeding recurrence or asymptomatic persistence is unknown following formation of a pulmonary artery false aneurysm.

Entities:  

Mesh:

Year:  2007        PMID: 17211167     DOI: 10.1097/ACO.0b013e32801158a9

Source DB:  PubMed          Journal:  Curr Opin Anaesthesiol        ISSN: 0952-7907            Impact factor:   2.706


  9 in total

1.  Catheter-induced pulmonary artery rupture: haemodynamic compromise necessitates surgical repair.

Authors:  Karen Lynsey Booth; Gavin Mercer-Smith; Chris McConkey; Haralabos Parissis
Journal:  Interact Cardiovasc Thorac Surg       Date:  2012-06-20

2.  Iatrogenic pulmonary artery rupture due to chest-tube insertion.

Authors:  Antonio Bozzani; Vittorio Arici; Guido Bellinzona; Stefano Pirrelli; Eugenio Forni; Attilio Odero
Journal:  Tex Heart Inst J       Date:  2010

Review 3.  Role of Interventional Radiology in the Management of Non-aortic Thoracic Trauma.

Authors:  Mikhail C S S Higgins; Jessica Shi; Mohammad Bader; Paul A Kohanteb; Tejal S Brahmbhatt
Journal:  Semin Intervent Radiol       Date:  2022-08-31       Impact factor: 1.780

4.  Pulmonary artery pseudoaneurysm after a left upper sleeve lobectomy.

Authors:  Minwei Bao; Yiming Zhou; Gening Jiang; Chang Chen
Journal:  World J Surg Oncol       Date:  2013-10-13       Impact factor: 2.754

5.  Endovascular treatment of PA pseudoaneurysm caused by Swan-Ganz catheter.

Authors:  Piotr N Rudziński; Marcin Demkow; Ilona Michałowska; Elżbieta Abramczuk; Piotr Szymański
Journal:  Postepy Kardiol Interwencyjnej       Date:  2014-03-23       Impact factor: 1.426

6.  Pulmonary artery rupture as a complication of Swan-Ganz catheter application. Diagnosis and endovascular treatment: a single centre's experience.

Authors:  Piotr N Rudziński; Jan Henzel; Zofia Dzielińska; Barbara M Lubiszewska; Ilona Michałowska; Piotr Szymański; Radosław Pracoń; Tomasz Hryniewiecki; Marcin Demkow
Journal:  Postepy Kardiol Interwencyjnej       Date:  2016-05-11       Impact factor: 1.426

7.  Pulmonary Artery Rupture Management with a Single Lumen Endotracheal Tube: Old Tricks that Should be Revisited.

Authors:  Thanuja Neerukonda; William J Gibson; Travis Abicht; Andrew Sauer; Brigid C Flynn
Journal:  Am J Case Rep       Date:  2018-03-24

8.  Fatal pulmonary haemorrhage following repeated intercostal drain insertions: Think before you re-do.

Authors:  Amit Rastogi; Shantanu Pandey; Ankita Singh; Shashank Tripathi
Journal:  Indian J Anaesth       Date:  2019-11-08

9.  Noninvasive cardiac output and blood pressure monitoring cannot replace an invasive monitoring system in critically ill patients.

Authors:  John F Stover; Reto Stocker; Renato Lenherr; Thomas A Neff; Silvia R Cottini; Bernhard Zoller; Markus Béchir
Journal:  BMC Anesthesiol       Date:  2009-10-12       Impact factor: 2.217

  9 in total