Literature DB >> 17210173

Wear of composite resin veneering materials and enamel in a chewing simulator.

Christian Mehl1, Soeren Scheibner, Klaus Ludwig, Matthias Kern.   

Abstract

OBJECTIVES: The purpose of this in vitro study was to evaluate the wear of six composite resins for the veneering of crowns compared with the wear of human and bovine enamel, tested in a dual-axis chewing simulator.
METHODS: Eight specimens of six different composite resins (Targis I+II, Solidex, BelleglassHP, Estenia, Solidex) and of human and bovine enamel were prepared. Steatite ceramic balls served as antagonistic specimens. Specimens were dynamically loaded in a dual-axis chewing simulator with 49 N up to 1,200,000 loading cycles with additional thermal cycling between 5 and 55 degrees C. After 120,000, 240,000, 480,000, 840,000 and 1,200,000 loading cycles, an impression of the specimens' surface and the antagonistic specimen was taken using a polyvinylsiloxane impression material. The substance loss at the surface was measured with computer-aided laser profilometry. Data were analyzed using ANOVA and the Tukey test.
RESULTS: The wear of the ultra fine compact filled composite resins Solidex and BelleglassHP was not statistically significantly different from that of human enamel. The other composite resins and bovine enamel showed a wear statistically significantly higher than human enamel. SIGNIFICANCE: Comparing six composite resins for the veneering of crowns, ultra fine compact filled composite resins BelleGlassHP and Solidex showed a wear not significantly different from the wear of human and bovine enamel.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17210173     DOI: 10.1016/j.dental.2006.11.026

Source DB:  PubMed          Journal:  Dent Mater        ISSN: 0109-5641            Impact factor:   5.304


  3 in total

1.  A comparative biomechanical study of original and compatible titanium bases: evaluation of screw loosening and 3D-crown displacement following cyclic loading analysis.

Authors:  Rimantas Ožiūnas; Jurgina Sakalauskienė; Darius Jegelevičius; Gintaras Janužis
Journal:  J Adv Prosthodont       Date:  2022-04-27       Impact factor: 1.989

2.  The use of Erbium: Yttrium-aluminum-garnet laser in cavity preparation and surface treatment: 3-year follow-up.

Authors:  Isil Buyukhatipoglu; Asli Secilmis
Journal:  Eur J Dent       Date:  2015 Apr-Jun

3.  Analysis of the Statistical Comparability of the Hardness and Wear of Polymeric Materials for Orthodontic Applications.

Authors:  Ivo Domagała; Krzysztof Przystupa; Marcel Firlej; Daniel Pieniak; Leszek Gil; Anna Borucka; Ireneusz Naworol; Barbara Biedziak; Mariana Levkiv
Journal:  Materials (Basel)       Date:  2021-05-28       Impact factor: 3.623

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.