Literature DB >> 17209119

The reliability of measuring physical characteristics of spiculated masses on mammography.

M P Sampat1, G J Whitman, T W Stephens, L D Broemeling, N A Heger, A C Bovik, M K Markey.   

Abstract

The goal of this study was to assess the reliability of measurements of the physical characteristics of spiculated masses on mammography. The images used in this study were obtained from the Digital Database for Screening Mammography. Two experienced radiologists measured the properties of 21 images of spiculated masses. The length and width of all spicules and the major axis of the mass were measured. In addition, the observers counted the total number of spicules. Interobserver and intraobserver variability were evaluated using a hypothesis test for equivalence, the intraclass correlation coefficient (ICC) and Bland-Altman statistics. For an equivalence level of 30% of the mean of the senior radiologist's measurement, equivalence was achieved for the measurements of average spicule length (p<0.01), average spicule width (p = 0.03), the length of the major axis (p<0.01) and for the count of the number of spicules (p<0.01). Similarly, with the ICC analysis technique "excellent" inter-rater agreement was observed for the measurements of average spicule length (ICC = 0.770), the length of the major axis (ICC = 0.801) and for the count of the number of spicules (ICC = 0.780). "Fair to good" agreement was observed for the average spicule width (ICC = 0.561). Equivalence was also demonstrated for intraobserver measurements. Physical properties of spiculated masses can be measured reliably on mammography. The interobserver and intraobserver variability for this task is comparable with that reported for other measurements made on medical images.

Mesh:

Year:  2006        PMID: 17209119     DOI: 10.1259/bjr/96723280

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  22 in total

1.  Acute benign vertebral compression fractures: "see-through sign" on contrast-enhanced MR images.

Authors:  Eugene Lee; Joon Woo Lee; Jinyoung Lee; Guen Young Lee; Woo Young Kang; Bo Reum Yoo; Yoon Joo Shin; Joong Mo Ahn; Heung Sik Kang
Journal:  Eur Spine J       Date:  2015-11-04       Impact factor: 3.134

2.  Painful type II os naviculare: introduction of a standardized, reproducible classification system.

Authors:  Sarah I Kamel; Jeffrey A Belair; Tarek M Hegazi; Ethan J Halpern; Vishal Desai; William B Morrison; Adam C Zoga
Journal:  Skeletal Radiol       Date:  2020-06-19       Impact factor: 2.199

3.  Radiographical measurements for distal intra-articular fractures of the radius using plain radiographs and cone beam computed tomography images.

Authors:  Nora Suojärvi; T Sillat; N Lindfors; S K Koskinen
Journal:  Skeletal Radiol       Date:  2015-08-14       Impact factor: 2.199

4.  Comparison of algorithms to enhance spicules of spiculated masses on mammography.

Authors:  Mehul P Sampat; Gary J Whitman; Alan C Bovik; Mia K Markey
Journal:  J Digit Imaging       Date:  2008-03       Impact factor: 4.056

5.  Evaluation of stylus for radiographic image annotation.

Authors:  Gautam S Muralidhar; Gary J Whitman; Tamara Miner Haygood; Tanya W Stephens; Alan C Bovik; Mia K Markey
Journal:  J Digit Imaging       Date:  2009-08-26       Impact factor: 4.056

6.  INTRA-RATER RELIABILITY OF THE MULTIPLE SINGLE-LEG HOP-STABILIZATION TEST AND RELATIONSHIPS WITH AGE, LEG DOMINANCE AND TRAINING.

Authors:  Leanne Sawle; Jennifer Freeman; Jonathan Marsden
Journal:  Int J Sports Phys Ther       Date:  2017-04

7.  Smaller but denser: postmortem changes alter the CT characteristics of subdural hematomas.

Authors:  Nicole Berger; Lars C Ebert; Garyfalia Ampanozi; Patricia M Flach; Dominic Gascho; Michael J Thali; Thomas D Ruder
Journal:  Forensic Sci Med Pathol       Date:  2015-01-08       Impact factor: 2.007

8.  Radiologist variability in assessing the position of the cavoatrial junction on chest radiographs.

Authors:  Tze Y Chan; Andrew England; Sara M Meredith; Richard G McWilliams
Journal:  Br J Radiol       Date:  2016-07-12       Impact factor: 3.039

9.  Usefulness of diffusion-weighted MR imaging for differentiating between benign and malignant superficial soft tissue tumours and tumour-like lesions.

Authors:  Ji Young Jeon; Hye Won Chung; Min Hee Lee; Sang Hoon Lee; Myung Jin Shin
Journal:  Br J Radiol       Date:  2016-02-19       Impact factor: 3.039

10.  Interobserver agreement after pipeline embolization device implantation.

Authors:  S H Suh; H J Cloft; G Lanzino; K Woodward; D F Kallmes
Journal:  AJNR Am J Neuroradiol       Date:  2012-12-28       Impact factor: 3.825

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.