Literature DB >> 17205487

Effect of signal-to-noise ratio and spectral linewidth on metabolite quantification at 4 T.

Robert Bartha1.   

Abstract

The accuracy and precision of measurements of metabolite concentrations from short echo-time spectra has previously been characterized at l.5 T as a function of signal-to-noise ratio (SNR) and peak linewidth. The purpose of this study was to characterize the systematic error in quantification of metabolite concentrations associated with linewidth and SNR for the major metabolites of interest in the short echo-time 1H-MR spectrum at 4 T. Simulated 4 T LASER localized spectra (TE = 46 ms) were generated with full width at half maximum (FWHM) over the range 4-14 Hz, and SNR over the range 5-500 by adding 100 Gaussian-distributed noise realizations at each combination of SNR and linewidth. Linewidth and SNR were treated as independent parameters, and therefore an increase in linewidth at a constant SNR resulted in increased metabolite areas. All spectra were fitted in the time domain using identical prior-knowledge and relative parameter starting values. Six metabolites (N-acetylaspartate, glutamate, creatine, myo-inositol, glycerophosphocholine, phosphocholine) were quantified with >90% accuracy and <10% standard deviation at SNR = 10 for linewidths ranging from 8 to 14 Hz FWHM. These simulations did not consider additional sources of variation, including eddy current artifacts, incomplete macromolecule baseline removal, and incomplete water suppression. Regardless, the results show that metabolite quantification from 4 T short echo-time 1H-MRS is sensitive to SNR and linewidth. Copyright 2007 John Wiley & Sons, Ltd.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17205487     DOI: 10.1002/nbm.1122

Source DB:  PubMed          Journal:  NMR Biomed        ISSN: 0952-3480            Impact factor:   4.044


  24 in total

1.  (1)H MR spectroscopy with external reference solution at 1.5 T for differentiating malignant and benign breast lesions: comparison using qualitative and quantitative approaches.

Authors:  Waka Mizukoshi; Eito Kozawa; Kaiji Inoue; Naoko Saito; Naoko Nishi; Toshiaki Saeki; Fumiko Kimura
Journal:  Eur Radiol       Date:  2012-07-10       Impact factor: 5.315

2.  Forebrain deletion of the vesicular acetylcholine transporter results in deficits in executive function, metabolic, and RNA splicing abnormalities in the prefrontal cortex.

Authors:  Benjamin Kolisnyk; Mohammed A Al-Onaizi; Pedro H F Hirata; Monica S Guzman; Simona Nikolova; Shahar Barbash; Hermona Soreq; Robert Bartha; Marco A M Prado; Vania F Prado
Journal:  J Neurosci       Date:  2013-09-11       Impact factor: 6.167

3.  Big GABA: Edited MR spectroscopy at 24 research sites.

Authors:  Mark Mikkelsen; Peter B Barker; Pallab K Bhattacharyya; Maiken K Brix; Pieter F Buur; Kim M Cecil; Kimberly L Chan; David Y-T Chen; Alexander R Craven; Koen Cuypers; Michael Dacko; Niall W Duncan; Ulrike Dydak; David A Edmondson; Gabriele Ende; Lars Ersland; Fei Gao; Ian Greenhouse; Ashley D Harris; Naying He; Stefanie Heba; Nigel Hoggard; Tun-Wei Hsu; Jacobus F A Jansen; Alayar Kangarlu; Thomas Lange; R Marc Lebel; Yan Li; Chien-Yuan E Lin; Jy-Kang Liou; Jiing-Feng Lirng; Feng Liu; Ruoyun Ma; Celine Maes; Marta Moreno-Ortega; Scott O Murray; Sean Noah; Ralph Noeske; Michael D Noseworthy; Georg Oeltzschner; James J Prisciandaro; Nicolaas A J Puts; Timothy P L Roberts; Markus Sack; Napapon Sailasuta; Muhammad G Saleh; Michael-Paul Schallmo; Nicholas Simard; Stephan P Swinnen; Martin Tegenthoff; Peter Truong; Guangbin Wang; Iain D Wilkinson; Hans-Jörg Wittsack; Hongmin Xu; Fuhua Yan; Chencheng Zhang; Vadim Zipunnikov; Helge J Zöllner; Richard A E Edden
Journal:  Neuroimage       Date:  2017-07-14       Impact factor: 6.556

4.  Limits of a localized magnetic resonance spectroscopy assay for ex vivo myocardial triacylglycerol.

Authors:  Robert D O'Connor; Robert J Gropler; Linda Peterson; Jean Schaffer; Joseph J H Ackerman
Journal:  J Pharm Biomed Anal       Date:  2007-09-01       Impact factor: 3.935

5.  Quantitative analysis of spatial averaging effect on chemical shift imaging SNR and noise coherence with k-space sampling schemes.

Authors:  Byeong-Yeul Lee; Xiao-Hong Zhu; Wei Chen
Journal:  Magn Reson Imaging       Date:  2019-03-31       Impact factor: 2.546

6.  Medial Frontal Lobe Neurochemistry in Autism Spectrum Disorder is Marked by Reduced N-Acetylaspartate and Unchanged Gamma-Aminobutyric Acid and Glutamate + Glutamine Levels.

Authors:  Andreia Carvalho Pereira; Inês R Violante; Susana Mouga; Guiomar Oliveira; Miguel Castelo-Branco
Journal:  J Autism Dev Disord       Date:  2018-05

7.  Comparison of reproducibility of single voxel spectroscopy and whole-brain magnetic resonance spectroscopy imaging at 3T.

Authors:  Yue Zhang; Edward Taub; Nouha Salibi; Gitendra Uswatte; Andrew A Maudsley; Sulaiman Sheriff; Brent Womble; Victor W Mark; David C Knight
Journal:  NMR Biomed       Date:  2018-02-13       Impact factor: 4.044

8.  Potential clinical impact of multiparametric quantitative MR spectroscopy in neurological disorders: A review and analysis.

Authors:  Ivan I Kirov; Assaf Tal
Journal:  Magn Reson Med       Date:  2019-08-08       Impact factor: 4.668

9.  Low-grade glioma: correlation of short echo time 1H-MR spectroscopy with 23Na MR imaging.

Authors:  R Bartha; J F Megyesi; C J Watling
Journal:  AJNR Am J Neuroradiol       Date:  2008-01-31       Impact factor: 3.825

10.  Optimized glutamate detection at 3T.

Authors:  Ileana Hancu
Journal:  J Magn Reson Imaging       Date:  2009-11       Impact factor: 4.813

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.