Literature DB >> 17204872

The use of rigid internal fixation in the surgical management of cervical spondylosis.

Brian K Kwon1, Alexander R Vaccaro, Jonathan N Grauer, John M Beiner.   

Abstract

In the surgical management of cervical spondylosis, the application of rigid internal fixation can enhance the immediate stability of the cervical spine. The sophistication of such internal fixation systems and the indications for their use are continuously evolving. A sound understanding of regional anatomy, biomechanics, and kinematics within the cervical spine is essential for the safe and effective application of internal fixation. Numerous options currently exist for anterior cervical plating systems; some lock the screws to the plate rigidly (constrained), whereas others allow for some rotational or translational motion between the screw and plate (semiconstrained). The role of anterior fixation in single and multilevel fusions is still the subject of some controversy. Long anterior cervical reconstructions may require additional posterior fixation to reliably promote fusion. Rigid fixation in the posterior cervical spine can be achieved with lateral mass screws or pedicle screws. Although lateral mass screws provide excellent fixation within the subaxial cervical spine, the regional anatomy of C2 and C7 often make it difficult to place such screws, and pedicle screws at these levels are advocated. Pedicle screws achieve fixation into both the anterior and posterior column and are arguably the most stable form of rigid internal fixation within the cervical spine. Familiarity with these internal fixation techniques can be an extremely valuable tool for the spine surgeon managing these degenerative disorders of the cervical spine.

Entities:  

Mesh:

Year:  2007        PMID: 17204872     DOI: 10.1227/01.NEU.0000249222.57709.59

Source DB:  PubMed          Journal:  Neurosurgery        ISSN: 0148-396X            Impact factor:   4.654


  8 in total

1.  Cervical anterior transpedicular screw fixation. Part I: Study on morphological feasibility, indications, and technical prerequisites.

Authors:  Heiko Koller; Axel Hempfing; Frank Acosta; Michael Fox; Armin Scheiter; Mark Tauber; Ulrich Holz; Herbert Resch; Wolfgang Hitzl
Journal:  Eur Spine J       Date:  2008-01-26       Impact factor: 3.134

2.  Posterior cervical fixation following laminectomy: a stress analysis of three techniques.

Authors:  Yang Duan; Hui Zhang; Shao-Xiong Min; Li Zhang; An-Min Jin
Journal:  Eur Spine J       Date:  2011-02-12       Impact factor: 3.134

3.  Effect of Ventral vs Dorsal Spinal Surgery on Patient-Reported Physical Functioning in Patients With Cervical Spondylotic Myelopathy: A Randomized Clinical Trial.

Authors:  Zoher Ghogawala; Norma Terrin; Melissa R Dunbar; Janis L Breeze; Karen M Freund; Adam S Kanter; Praveen V Mummaneni; Erica F Bisson; Fred G Barker; J Sanford Schwartz; James S Harrop; Subu N Magge; Robert F Heary; Michael G Fehlings; Todd J Albert; Paul M Arnold; K Daniel Riew; Michael P Steinmetz; Marjorie C Wang; Robert G Whitmore; John G Heller; Edward C Benzel
Journal:  JAMA       Date:  2021-03-09       Impact factor: 56.272

4.  Cervical spondylotic myelopathy surgical trial: randomized, controlled trial design and rationale.

Authors:  Zoher Ghogawala; Edward C Benzel; Robert F Heary; K Daniel Riew; Todd J Albert; William E Butler; Fred G Barker; John G Heller; Paul C McCormick; Robert G Whitmore; Karen M Freund; J Sanford Schwartz
Journal:  Neurosurgery       Date:  2014-10       Impact factor: 4.654

5.  In vitro study of accuracy of cervical pedicle screw insertion using an electronic conductivity device (ATPS part III).

Authors:  Heiko Koller; Wolfgang Hitzl; Frank Acosta; Mark Tauber; Juliane Zenner; Herbert Resch; Yasutsugu Yukawa; Oliver Meier; Rene Schmidt; Michael Mayer
Journal:  Eur Spine J       Date:  2009-07-03       Impact factor: 3.134

6.  Posterior cervical fixation with nitinol shape memory loop in the anterior-posterior combined approach for the patients with three column injury of the cervical spine : preliminary report.

Authors:  Dong-Kun Yu; Dong-Hwa Heo; Sung-Min Cho; Jong-Hun Choi; Seung-Hun Sheen; Yong-Jun Cho
Journal:  J Korean Neurosurg Soc       Date:  2008-11-30

7.  Is polymethyl methacrylate a viable option for salvaging lateral mass screw failure in the subaxial cervical spine?

Authors:  Michael A Gallizzi; Craig A Kuhns; Tyler J Jenkins; Ferris M Pfeiffer
Journal:  Global Spine J       Date:  2014-10-10

8.  The Feasibility of Translaminar Screws in the Subaxial Cervical Spine: Computed Tomography and Cadaveric Validation.

Authors:  Woojin Cho; Jason T Le; Adam L Shimer; Brian C Werner; John A Glaser; Francis H Shen
Journal:  Clin Orthop Surg       Date:  2022-02-15
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.