Literature DB >> 17202626

Performance comparison of six independent components analysis algorithms for fetal signal extraction from real fMCG data.

Kenneth E Hild1, Giovanna Alleva, Srikantan Nagarajan, Silvia Comani.   

Abstract

In this study we compare the performance of six independent components analysis (ICA) algorithms on 16 real fetal magnetocardiographic (fMCG) datasets for the application of extracting the fetal cardiac signal. We also compare the extraction results for real data with the results previously obtained for synthetic data. The six ICA algorithms are FastICA, CubICA, JADE, Infomax, MRMI-SIG and TDSEP. The results obtained using real fMCG data indicate that the FastICA method consistently outperforms the others in regard to separation quality and that the performance of an ICA method that uses temporal information suffers in the presence of noise. These two results confirm the previous results obtained using synthetic fMCG data. There were also two notable differences between the studies based on real and synthetic data. The differences are that all six ICA algorithms are independent of gestational age and sensor dimensionality for synthetic data, but depend on gestational age and sensor dimensionality for real data. It is possible to explain these differences by assuming that the number of point sources needed to completely explain the data is larger than the dimensionality used in the ICA extraction.

Entities:  

Mesh:

Year:  2006        PMID: 17202626     DOI: 10.1088/0031-9155/52/2/010

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  3 in total

1.  Independent component analysis of normal and abnormal rhythm in twin pregnancies.

Authors:  Nana Aba Mensah-Brown; William J Lutter; Silvia Comani; Janette F Strasburger; Ronald T Wakai
Journal:  Physiol Meas       Date:  2010-11-19       Impact factor: 2.833

2.  Segmented independent component analysis for improved separation of fetal cardiac signals from nonstationary fetal magnetocardiograms.

Authors:  Luiz O Murta; Mauro G Guzo; Eder R Moraes; Oswaldo Baffa; Ronald T Wakai; Silvia Comani
Journal:  Biomed Tech (Berl)       Date:  2015-06       Impact factor: 1.411

3.  Linear and nonlinear measures of fetal heart rate patterns evaluated on very short fetal magnetocardiograms.

Authors:  Eder Rezende Moraes; Luiz Otavio Murta; Oswaldo Baffa; Ronald T Wakai; Silvia Comani
Journal:  Physiol Meas       Date:  2012-09-04       Impact factor: 2.833

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.