Literature DB >> 17201852

Optimization of device programming for cardiac resynchronization therapy.

Haran Burri1, Henri Sunthorn, Dipen Shah, René Lerch.   

Abstract

Cardiac resynchronization therapy may lead to remarkable improvement in clinical status in selected patients with heart failure. However, approximately 20-30% of patients may not respond to this treatment. One of the reasons for this may be suboptimal programming of the device, which has particular considerations as compared to standard pacemakers. Hemodynamic response to pacing may be affected by timing of the atrioventricular (AV) interval, affecting synchronicity of atrial and ventricular contraction. In addition current biventricular devices have separate right and left ventricular channels that allow programming of an interventricular (VV) interval with right or left ventricular preexcitation. This article focuses on the parameters that may be optimized for biventricular pacing, and reviews the different techniques currently available for this application, with special emphasis paid to echocardiography.

Entities:  

Mesh:

Year:  2006        PMID: 17201852     DOI: 10.1111/j.1540-8159.2006.00557.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  5 in total

1.  Measurement precision in the optimization of cardiac resynchronization therapy.

Authors:  Robert G Turcott; Ronald M Witteles; Paul J Wang; Randall H Vagelos; Michael B Fowler; Euan A Ashley
Journal:  Circ Heart Fail       Date:  2010-02-22       Impact factor: 8.790

2.  Optimization of cardiac resynchronization therapy after implantation.

Authors:  Ayesha Hasan; William T Abraham
Journal:  Curr Treat Options Cardiovasc Med       Date:  2008-08

3.  Using devices with a variable postventricular atrial refractory period for cardiac resynchronization.

Authors:  S S Barold; R X Stroobandt
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2012-03

4.  Simultaneous variation of ventricular pacing site and timing with biventricular pacing in acute ventricular failure improves function by interventricular assist.

Authors:  T Alexander Quinn; Santos E Cabreriza; Marc E Richmond; Alan D Weinberg; Jeffrey W Holmes; Henry M Spotnitz
Journal:  Am J Physiol Heart Circ Physiol       Date:  2009-10-23       Impact factor: 4.733

5.  Exploratory cost-effectiveness analysis of cardiac resynchronization therapy with systematic device optimization vs. standard (non-systematic) optimization: a multinational economic evaluation.

Authors:  Kurt Banz; Peter Paul Delnoy; Jean Renaud Billuart
Journal:  Health Econ Rev       Date:  2015-07-11
  5 in total