Literature DB >> 17201017

Does three-dimensional power Doppler ultrasound help in discrimination between benign and malignant ovarian masses?

L Jokubkiene1, P Sladkevicius, L Valentin.   

Abstract

OBJECTIVES: To determine if tumor vascularity as assessed by three-dimensional (3D) power Doppler ultrasound can be used to discriminate between benign and malignant ovarian tumors, if adding 3D power Doppler ultrasound to gray-scale imaging improves differentiation between benignity and malignancy, and if 3D power Doppler ultrasound adds more to gray-scale ultrasound than does two-dimensional (2D) power Doppler ultrasound.
METHODS: One hundred and six women scheduled for surgery because of an ovarian mass were examined with transvaginal gray-scale ultrasound and 2D and 3D power Doppler ultrasound. The color content of the tumor scan was rated subjectively by the ultrasound examiner on a visual analog scale. Vascularization index (VI), flow index (FI) and vascularization flow index (VFI) were calculated in the whole tumor and in a 5-cm(3) sample taken from the most vascularized area of the tumor. Logistic regression analysis was used to build models to predict malignancy.
RESULTS: There were 79 benign tumors, six borderline tumors and 21 invasive malignancies. A logistic regression model including only gray-scale ultrasound variables (the size of the largest solid component, wall irregularity, and lesion size) was built to predict malignancy. It had an area under the receiver-operating characteristics (ROC) curve of 0.98, sensitivity of 100%, false positive rate of 10%, and positive likelihood ratio (LR) of 10 when using the mathematically best cut-off value for risk of malignancy (0.12). The diagnostic performance of the 3D flow index with the best diagnostic performance, i.e. VI in a 5-cm(3) sample, was superior to that of the color content of the tumor scan (area under ROC curve 0.92 vs. 0.80, sensitivity 93% vs. 78%, false positive rate 16% vs. 27% using the mathematically best cut-off value). Adding the color content of the tumor scan or FI in a 5-cm(3) sample to the logistic regression model including the three gray-scale variables described above improved diagnostic performance only marginally, an additional two tumors being correctly classified.
CONCLUSIONS: Even though 2D and 3D power Doppler ultrasound can be used to discriminate between benign and malignant ovarian tumors, their use adds little to a correct diagnosis of malignancy in an ordinary population of ovarian tumors. Objective quantitation of the color content of the tumor scan using 3D power Doppler ultrasound does not seem to add more to gray-scale imaging than does subjective quantitation by the ultrasound examiner using 2D power Doppler ultrasound. Copyright 2007 ISUOG. Published by John Wiley & Sons, Ltd.

Entities:  

Mesh:

Year:  2007        PMID: 17201017     DOI: 10.1002/uog.3922

Source DB:  PubMed          Journal:  Ultrasound Obstet Gynecol        ISSN: 0960-7692            Impact factor:   7.299


  12 in total

1.  Usefulness of transabdominal real-time sonoelastography in the evaluation of ovarian lesions: preliminary results.

Authors:  Duygu Herek; Aysun Karabulut; Kadir Agladioglu
Journal:  Br J Radiol       Date:  2016-06-28       Impact factor: 3.039

2.  Risk of malignancy index is not sensitive in detecting non-epithelial ovarian cancer and borderline ovarian tumor.

Authors:  Onur Meray; Ilgın Türkçüoğlu; Mehmet Mutlu Meydanlı; Ayşe Kafkaslı
Journal:  J Turk Ger Gynecol Assoc       Date:  2010-03-01

3.  Evaluation of selected ultrasonographic parameters and marker levels in the preoperative differentiation of borderline ovarian tumors and ovarian cancers.

Authors:  Piotr Sobiczewski; Anna Dańska-Bidzińska; Jakub Rzepka; Jolanta Kupryjańczyk; Mariusz Gujski; Mariusz Bidziński; Wojciech Michalski
Journal:  Arch Gynecol Obstet       Date:  2012-07-21       Impact factor: 2.344

4.  The role of 3-dimensional power Doppler imaging in the assessment of ovarian teratoma in pregnancy: a case report.

Authors:  Konstantinos Kalmantis; Christos Iavazzo; Vasiliki Anastasiadou; Aris Antsaklis
Journal:  Case Rep Med       Date:  2011-08-25

Review 5.  Ultrasound evaluation of ovarian masses and assessment of the extension of ovarian malignancy.

Authors:  Francesca Moro; Rosanna Esposito; Chiara Landolfo; Wouter Froyman; Dirk Timmerman; Tom Bourne; Giovanni Scambia; Lil Valentin; Antonia Carla Testa
Journal:  Br J Radiol       Date:  2021-06-09       Impact factor: 3.629

6.  Limitations of three-dimensional power Doppler angiography in preoperative evaluation of ovarian tumors.

Authors:  Liliane Silvestre; Wellington P Martins; Francisco J Candido-Dos-Reis
Journal:  J Ovarian Res       Date:  2015-07-29       Impact factor: 4.234

7.  GyneScan: an improved online paradigm for screening of ovarian cancer via tissue characterization.

Authors:  U Rajendra Acharya; S Vinitha Sree; Sanjeev Kulshreshtha; Filippo Molinari; Joel En Wei Koh; Luca Saba; Jasjit S Suri
Journal:  Technol Cancer Res Treat       Date:  2013-12-06

8.  The contribution of qualitative CEUS to the determination of malignancy in adnexal masses, indeterminate on conventional US - a multicenter study.

Authors:  Xinling Zhang; Yongjiang Mao; Rongqin Zheng; Zhijuan Zheng; Zeping Huang; Dongmei Huang; Jing Zhang; Qing Dai; Xiaodong Zhou; Yanling Wen
Journal:  PLoS One       Date:  2014-04-15       Impact factor: 3.240

9.  A new scoring model for characterization of adnexal masses based on two-dimensional gray-scale and colour Doppler sonographic features.

Authors:  A M Abbas; K M Zahran; A Nasr; H S Kamel
Journal:  Facts Views Vis Obgyn       Date:  2014

10.  Reliability of preoperative evaluation of postmenopausal ovarian tumors.

Authors:  Riikka Johanna Niemi; Sami Kristian Saarelainen; Tiina Hannele Luukkaala; Johanna Unelma Mäenpää
Journal:  J Ovarian Res       Date:  2017-03-14       Impact factor: 4.234

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.