Literature DB >> 17200811

Membrane thickness design of implantable bio-MEMS sensors for the in-situ monitoring of blood flow.

C A Steeves1, Y L Young, Z Liu, A Bapat, K Bhalerao, A B O Soboyejo, W O Soboyejo.   

Abstract

This paper presents some ideas for the membrane thickness design of of implantable bio-micro-electro-mechanical systems (bio-MEMS) for the in situ monitoring of blood flow. The objective is to develop a smart wireless sensing unit for non-invasive early stenosis detection in heart bypass grafts. The design includes considerations of nonlinear material models, multiscale blood flows, and appropriate analyical models for data interpretation, as well as preliminary studies of the pressure and flow sensing concepts. The paper also examines the use of surface coatings for the design on biocompatibility and non-adhesion of blood platelets and constituents. The implications of the results are discussed for in vivo deployment of such sensor systems.

Mesh:

Substances:

Year:  2007        PMID: 17200811     DOI: 10.1007/s10856-006-0659-8

Source DB:  PubMed          Journal:  J Mater Sci Mater Med        ISSN: 0957-4530            Impact factor:   3.896


  32 in total

Review 1.  Numerical modeling of pulsatile turbulent flow in stenotic vessels.

Authors:  Sonu S Varghese; Steven H Frankel
Journal:  J Biomech Eng       Date:  2003-08       Impact factor: 2.097

2.  Hemodynamic effects of arterial stenosis.

Authors:  A G MAY; J A DE WEESE; C G ROB
Journal:  Surgery       Date:  1963-04       Impact factor: 3.982

3.  Steady laminar flow through modelled vascular stenoses.

Authors:  M D Deshpande; D P Giddens; R F Mabon
Journal:  J Biomech       Date:  1976       Impact factor: 2.712

4.  Slow crack growth in single-crystal silicon.

Authors:  J A Connally; S B Brown
Journal:  Science       Date:  1992-06-12       Impact factor: 47.728

5.  Pressure drop across artificially induced stenoses in the femoral arteries of dogs.

Authors:  D F Young; N R Cholvin; A C Roth
Journal:  Circ Res       Date:  1975-06       Impact factor: 17.367

6.  Pulsatile flow of non-Newtonian fluids through arterial stenoses.

Authors:  C Tu; M Deville
Journal:  J Biomech       Date:  1996-07       Impact factor: 2.712

7.  Static anisotropic elastic properties of the aorta in living dogs.

Authors:  D J Patel; J S Janicki; T E Carew
Journal:  Circ Res       Date:  1969-12       Impact factor: 17.367

8.  A non-Newtonian fluid model for blood flow through arteries under stenotic conditions.

Authors:  J C Misra; M K Patra; S C Misra
Journal:  J Biomech       Date:  1993-09       Impact factor: 2.712

9.  An improved microindentation technique to measure changes in properties of arterial intima during atherogenesis.

Authors:  B S Gow; W D Castle; M J Legg
Journal:  J Biomech       Date:  1983       Impact factor: 2.712

10.  Changes in the microindentation properties of aortic intimal surface during cholesterol feeding of rabbits.

Authors:  W D Castle; B S Gow
Journal:  Atherosclerosis       Date:  1983-06       Impact factor: 5.162

View more
  4 in total

Review 1.  Microfabricated implants for applications in therapeutic delivery, tissue engineering, and biosensing.

Authors:  Kristy M Ainslie; Tejal A Desai
Journal:  Lab Chip       Date:  2008-09-19       Impact factor: 6.799

2.  Design of a customized multipurpose nano-enabled implantable system for in-vivo theranostics.

Authors:  Esteve Juanola-Feliu; Pere Ll Miribel-Català; Cristina Páez Avilés; Jordi Colomer-Farrarons; Manel González-Piñero; Josep Samitier
Journal:  Sensors (Basel)       Date:  2014-10-16       Impact factor: 3.576

3.  A smartphone-enabled wireless and batteryless implantable blood flow sensor for remote monitoring of prosthetic heart valve function.

Authors:  Bernhard Vennemann; Dominik Obrist; Thomas Rösgen
Journal:  PLoS One       Date:  2020-01-14       Impact factor: 3.240

Review 4.  Microelectromechanical Systems Based on Magnetic Polymer Films.

Authors:  Denisa Ficai; Marin Gheorghe; Georgiana Dolete; Bogdan Mihailescu; Paul Svasta; Anton Ficai; Gabriel Constantinescu; Ecaterina Andronescu
Journal:  Micromachines (Basel)       Date:  2022-02-23       Impact factor: 2.891

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.