Prehospital emergency endotracheal intubation using the Bonfils intubation fiberscope.

Christian Byhahn1, Dirk Meininger, Felix Walcher, Christian Hofstetter, Bernhard Zwissler.   

Abstract

Among all prehospital emergency intubations, difficulties occur in 7-10%. Furthermore, intubation conditions often worsen when the cervical spine is immobilized in trauma patients. We report on six patients in whom the Bonfils intubation fiberscope, a reusable, rigid fiberoptic device, was used for emergency endotracheal intubation in the field. Three of these patients had an anticipated or unanticipated difficult airway: two trauma patients with immobilized cervical spine and one patient in cardiac arrest in whom direct laryngoscopy failed twice. Endotracheal intubation with the Bonfils intubation fiberscope was successful in all cases in the first attempt. The Bonfils intubation fiberscope therefore demonstrated its value as an additional airway management device in both emergency and prehospital settings.

Entities:  

Mesh:

Year:  2007        PMID: 17198327     DOI: 10.1097/01.mej.0000195680.08533.57

Source DB:  PubMed          Journal:  Eur J Emerg Med        ISSN: 0969-9546            Impact factor:   2.799


  5 in total

1.  Emergency airway management using the Bonfils intubation fiberscope.

Authors:  Ruggero M Corso; Giorgio Gambale; Emanuele Piraccini; Flavia Petrini
Journal:  Intern Emerg Med       Date:  2010-03-10       Impact factor: 3.397

Review 2.  [Indirect laryngoscopy : Alternatives to securing the airway].

Authors:  R R Noppens; C Werner; T Piepho
Journal:  Anaesthesist       Date:  2010-02       Impact factor: 1.041

3.  Improving rigid fiberoptic intubation: a comparison of the Bonfils Intubating Fiberscope with a novel modification.

Authors:  Ben H Boedeker; Mary A Barak-Bernhagen; David J Miller; Thomas A Nicholas; Andrew Linnaus; W B Murray
Journal:  BMC Emerg Med       Date:  2010-05-27

4.  Hemodynamic responses to tracheal intubation with Bonfils compared to C-MAC videolaryngoscope: a randomized trial.

Authors:  Youssef Ezhar; Frederick D'Aragon; Pablo Echave
Journal:  BMC Anesthesiol       Date:  2018-09-07       Impact factor: 2.217

5.  Rigid fibrescope Bonfils: use in simulated difficult airway by novices.

Authors:  Tim Piepho; Rüdiger R Noppens; Florian Heid; Christian Werner; Andreas R Thierbach
Journal:  Scand J Trauma Resusc Emerg Med       Date:  2009-07-22       Impact factor: 2.953