Literature DB >> 17197303

The significance of metal staining on alumina femoral heads in total hip arthroplasty.

B Sonny Bal1, Mohamed N Rahaman, Thomas Aleto, F Scott Miller, Francesco Traina, Aldo Toni.   

Abstract

Metallic transfer to alumina can occur intraoperatively and while reducing a dislocated total hip, when the femoral head contacts the rim of the metal acetabular shell. To see if metal discoloration is associated with changes to the alumina, we examined 14 metal-stained alumina femoral heads retrieved from ceramic-on-ceramic articulations using electron microscopy and noncontact profilometry. Metal staining was associated with surface damage to alumina on the femoral heads removed from unstable total hips. The surface roughness of metal-stained alumina heads was significantly greater than that of unused alumina heads. Alumina femoral heads should be protected against contact with the metal cup during total hip implantation. Dislocations in ceramic-on-ceramic total hips should be addressed early because of possible damage to the surface.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17197303     DOI: 10.1016/j.arth.2006.02.155

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  7 in total

1.  High incidence of squeaking in THAs with alumina ceramic-on-ceramic bearings.

Authors:  J C Keurentjes; R M Kuipers; D J Wever; B W Schreurs
Journal:  Clin Orthop Relat Res       Date:  2008-02-26       Impact factor: 4.176

2.  A review of protein adsorption on bioceramics.

Authors:  Kefeng Wang; Changchun Zhou; Youliang Hong; Xingdong Zhang
Journal:  Interface Focus       Date:  2012-03-22       Impact factor: 3.906

3.  Ceramic-on-ceramic total hip arthroplasty: incidence of instability and noise.

Authors:  David Schroder; Lindsey Bornstein; Mathias P G Bostrom; Bryan J Nestor; Douglas E Padgett; Geoffrey H Westrich
Journal:  Clin Orthop Relat Res       Date:  2011-02       Impact factor: 4.176

4.  A simulator study of adverse wear with metal and cement debris contamination in metal-on-metal hip bearings.

Authors:  T Halim; I C Clarke; M D Burgett-Moreno; T K Donaldson; C Savisaar; J G Bowsher
Journal:  Bone Joint Res       Date:  2014-03       Impact factor: 5.853

5.  Raman and Photoemission Spectroscopic Analyses of Explanted Biolox® Delta Femoral Heads Showing Metal Transfer.

Authors:  Paola Taddei; Eleonora Pavoni; Saverio Affatato
Journal:  Materials (Basel)       Date:  2017-07-03       Impact factor: 3.623

6.  Experimental Investigation of Material Transfer on Bearings for Total Hip Arthroplasty-A Retrieval Study on Ceramic and Metallic Femoral Heads.

Authors:  Jessica Hembus; Lisa Rößler; Armin Springer; Marcus Frank; Annett Klinder; Rainer Bader; Carmen Zietz; Andreas Enz
Journal:  J Clin Med       Date:  2022-07-07       Impact factor: 4.964

7.  Does Metal Transfer Differ on Retrieved Ceramic and CoCr Femoral Heads?

Authors:  Eliza K Fredette; Daniel W MacDonald; Richard J Underwood; Antonia F Chen; Michael A Mont; Gwo-Chin Lee; Gregg R Klein; Clare M Rimnac; Steven M Kurtz
Journal:  Biomed Res Int       Date:  2015-10-25       Impact factor: 3.411

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.