Evaluation of methods for sorting CCA-treated wood.

Gary Jacobi1, Helena Solo-Gabriele, Timothy Townsend, Brajesh Dubey.   

Abstract

Construction and demolition (C&amp;D) wood frequently contains treated wood including wood treated with chromated copper arsenate (CCA). Many recycling options for such wood require that the product be essentially free of preservative chemicals. The objectives of this study were to document the characteristics of the wood waste stream and to evaluate the effectiveness of sorting methods for identifying treated wood. Sorting methods evaluated included visual sorting and visual sorting augmented with the use of PAN indicator stain and/or hand-held X-ray fluorescence (XRF) units. Experiments were conducted on two types of construction and demolition (C&amp;D) wood: source separated loads containing only C&amp;D wood and wood hand-picked from commingled loads of general C&amp;D waste. Results showed that 77% of the treated wood was CCA-treated. For uncontaminated piles (<1% treated wood) of source separated C&amp;D wood, visual sorting was found to effectively remove the small amounts of treated wood present. For piles of source separated wood that were contaminated (approximately 50% treated wood), visual sorts were not accurate and benefited from augmented sorting using PAN indicator stain. The handheld XRF devices were found to be effective for sorting commingled C&amp;D wood, as PAN indicator stain was not as effective due to the excessive amount of surface dirt associated with commingled wood waste. Visual sorting of source separated wood was estimated to cost between US$21 to US$96 per metric ton. These costs depended upon the amount of treated wood and whether or not augmentation with PAN indicator was necessary. Visual sorting augmented with hand-held XRF units was estimated at US$113 per metric ton. The bulk of these costs were associated with labor. Future efforts should focus on reducing labor costs by mounting automated XRF units on conveyor systems.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17197165     DOI: 10.1016/j.wasman.2006.09.014

Source DB:  PubMed          Journal:  Waste Manag        ISSN: 0956-053X            Impact factor:   7.145


  4 in total

1.  Use of handheld X-ray fluorescence spectrometry units for identification of arsenic in treated wood.

Authors:  Colleen N Block; Tomoyuki Shibata; Helena M Solo-Gabriele; Timothy G Townsend
Journal:  Environ Pollut       Date:  2007-01-22       Impact factor: 8.071

2.  Quantities of arsenic-treated wood in demolition debris generated by Hurricane Katrina.

Authors:  Brajesh Dubey; Helena M Solo-Gabriele; Timothy G Townsendt
Journal:  Environ Sci Technol       Date:  2007-03-01       Impact factor: 9.028

3.  Variation of arsenic concentration on surfaces of in-service CCA-treated wood planks in a park and its influencing field factors.

Authors:  Ya Tang; Wei Gao; Xiuli Wang; Shiming Ding; Taicheng An; Weiyang Xiao; Ming H Wong; Chaosheng Zhang
Journal:  Environ Monit Assess       Date:  2014-12-16       Impact factor: 2.513

4.  Risk Assessment for Children Exposed to Arsenic on Baseball Fields with Contaminated Fill Material.

Authors:  Alesia C Ferguson; Jennifer C Black; Isaac B Sims; Jennifer N Welday; Samir M Elmir; Kendra F Goff; J Mark Higginbotham; Helena M Solo-Gabriele
Journal:  Int J Environ Res Public Health       Date:  2018-01-04       Impact factor: 3.390