Literature DB >> 17196742

A sub-second fast Fourier transform-adsorptive voltammetric technique for the nano-level determination of guthion at a gold microelectrode in flowing solutions.

Gholamreza Nabi Bidhendi1, Parviz Norouzi, Parandis Daneshgar, Mohammad Reza Ganjali.   

Abstract

This research demonstrates the quick guthion monitoring with the help of a sensitive method called fast Fourier transformation continuous cyclic voltammetry (FFTCV). Fortunately, FFTCV illustrates the benefits of precision, determination speed, cost-effectiveness, accuracy and simplicity, in comparison with formerly reported techniques. In particular, this method was applied to a gold microelectrode in flowing solutions to detect the guthion concentration in its formulations. The effects of several parameters were examined regarding the sensitivity of the method. After a series of experiments, the detection limit of the method was found to be equal to 1.27 pg/mL, when the optimum conditions were imposed, which is a scan rate value of 40V/s, an accumulation time of 0.4s, an accumulation potential of 0mV and a pH value of 2. During the measurements performance, the integration range of currents included all the potential scan ranges, even the oxidation and reduction of the Au surface electrode, for the achievement of a sensitive determination. Then, the potential waveform, consisting of the potential steps for cleaning, accumulation and the step for the potential ramp, was applied to an Au disk microelectrode in a continuous way. It is also important to refer to the positive points, presented only by the use of this technique. Firstly, it is no longer necessary to remove the oxygen from the test solution. Furthermore, the quick determination of any such compound in many chromatographic methods is possible. Thirdly, the corresponding detection limit is of nanomolar level.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17196742     DOI: 10.1016/j.jhazmat.2006.09.022

Source DB:  PubMed          Journal:  J Hazard Mater        ISSN: 0304-3894            Impact factor:   10.588


  1 in total

1.  Determination of diclofenac on a dysprosium nanowire- modified carbon paste electrode accomplished in a flow injection system by advanced filtering.

Authors:  Parandis Daneshgar; Parviz Norouzi; Mohammad Reza Ganjali; Rasoul Dinarvand; Ali Akbar Moosavi-Movahedi
Journal:  Sensors (Basel)       Date:  2009-09-30       Impact factor: 3.576

  1 in total