Application of heated inlet extensions to the TSI 3306/3321 system: comparison with the Andersen cascade impactor and next generation impactor.

Paul B Myrdal1, Erik Mogalian, Jolyon Mitchell, Mark Nagel, Charlie Wright, Brent Kiser, Mark Prell, Mike Woessner, Stephen W Stein.   

Abstract

Pharmaceutical aerosol size distribution analysis based on multi-stage inertial impaction is well accepted, though laborious. The TSI 3306 Impactor Inlet/3321 time-of-flight (TOF) Aerodynamic Particle Size Analyzer (APS) has been evaluated for its ease of use and potential for time savings during product development. However, instrument inlet modifications may be necessary for increased correlation with equivalent measurements obtained by inertial impaction following pharmacopeial methods. A heated inlet extension tube was located between the USP/Ph.Eur. throat and the Single-Stage Impactor (SSI) to promote evaporation of residual ethanol from aerosol droplets, generated from two formulations containing ethanol as semi-volatile solubilizer (8 and 20% w/w) for the active pharmaceutical ingredient. As temperature and extension length increased, the SSI-measured fine particle fraction (aerosol < 4.7 microm aerodynamic diameter) also increased, for the aerosols used in this study. These values correlated quite closely with equivalent measures made by multi-stage cascade impactor equipped with the same throat. Particle size distribution profiles measured with the APS for either formulation did not significantly change utilizing the heated extensions, suggesting that ethanol evaporation was largely complete at any condition by the time the aerosol entered the measurement zone of the TOF analyzer. The addition of a heated inlet extension may be useful to facilitate evaporation of residual semi-volatile species, especially when an agreement of APS-derived particle size mass distribution data from the SSI with multi-stage cascade impactors is desired. However, complete evaporation of the semi-volatile species may not be necessary for SSI-generated mass distribution to match conventionally used cascade impactors.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17196082     DOI: 10.1089/jam.2006.19.543

Source DB:  PubMed          Journal:  J Aerosol Med        ISSN: 0894-2684


  2 in total

1.  The abbreviated impactor measurement (AIM) concept: part II--Influence of evaporation of a volatile component-evaluation with a "droplet-producing" pressurized metered dose inhaler (pMDI)-based formulation containing ethanol as cosolvent.

Authors:  J P Mitchell; M W Nagel; V Avvakoumova; H MacKay; R Ali
Journal:  AAPS PharmSciTech       Date:  2009-03-17       Impact factor: 3.246

Review 2.  Non-impactor-based methods for sizing of aerosols emitted from orally inhaled and nasal drug products (OINDPs).

Authors:  Jolyon Mitchell; Richard Bauer; Svetlana Lyapustina; Terrence Tougas; Volker Glaab
Journal:  AAPS PharmSciTech       Date:  2011-07-22       Impact factor: 3.246

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.