Literature DB >> 17195203

Stent fracture associated with drug-eluting stents: clinical characteristics and implications.

Michael S Lee1, Daniel Jurewitz, Joseph Aragon, James Forrester, Raj R Makkar, Saibal Kar.   

Abstract

OBJECTIVE: To evaluate the clinical characteristics and implications of stent fracture in drug-eluting stents.
BACKGROUND: Approximately 2.5 million drug-eluting stents are implanted every year worldwide. In 10 randomized controlled trials involving 2,602 patients, no incidence of stent fracture was recognized or reported.
METHODS: From April 2003 to December 2005, 2,728 patients underwent drug-eluting stenting. The angiograms of all 530 patients who underwent repeat angiography were analyzed to identify the presence of stent fracture. We then documented the incidence of adverse events associated with drug-eluting stent fracture and systematically analyzed the clinical, procedural, and structural factors, which might predispose to stent fracture.
RESULTS: Stent fracture was identified in 10 patients. None of these fractures were detectable at the time of stent placement. The median time interval from stent implantation to detection of fracture at repeat angiography was 226 days (range, 7-620 days). Adverse clinical outcomes associated with stent fracture occurred in 7 patients (6 patients had binary restenosis and 1 patient had stent thrombosis), all necessitating repeat intervention. Analysis of potential predisposing clinical, procedural, and structural factors revealed that 4 patients had excessive tortuosity in the proximal segment, and overlapping stents were used in 5 cases. All fractures occurred in sirolimus-eluting stents.
CONCLUSIONS: Stent fracture may represent a new potential mechanism of restenosis and stent thrombosis in drug-eluting stents. Predisposing clinical and procedural factors may be vessel tortuosity and use of overlapping stents. The most important predisposing factor, however, may be stent structure, since all fractures occurred in sirolimus-eluting stents. (c) 2006 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17195203     DOI: 10.1002/ccd.20942

Source DB:  PubMed          Journal:  Catheter Cardiovasc Interv        ISSN: 1522-1946            Impact factor:   2.692


  32 in total

1.  Prevalence and prognosis of coronary stent gap detected by multi-detector CT: a follow-up study.

Authors:  Xinghua Zhang; Li Yang; Haiyue Ju; Fan Zhang; Jian Wu; Bin He; Yundai Chen
Journal:  Eur Radiol       Date:  2012-04-27       Impact factor: 5.315

2.  Surgical treatment of entrapped intravascular ultrasonography catheter.

Authors:  Yusuke Shimahara; Junjiro Kobayashi; Hiroyuki Nakajima; Koichi Toda; Tomoyuki Fujita
Journal:  Gen Thorac Cardiovasc Surg       Date:  2012-02-12

3.  Circumferential stent fracture: novel detection and treatment with the use of StentBoost.

Authors:  Raghu T Ramegowda; Srinivas B Chikkaswamy; Ashalatha Bharatha; Jayashree Radhakrishna; Geetha B Krishnanaik; Manjunath C Nanjappa; Arunkumar Panneerselvam
Journal:  Tex Heart Inst J       Date:  2012

4.  Stent fracture and longitudinal compression detected on coronary CT angiography in the first- and new-generation drug-eluting stents.

Authors:  Mi Sun Chung; Dong Hyun Yang; Young-Hak Kim; Jae-Hyung Roh; Jihyun Song; Joon-Won Kang; Jung-Min Ahn; Duk-Woo Park; Soo-Jin Kang; Seung-Whan Lee; Cheol Whan Lee; Seong-Wook Park; Seung-Jung Park; Tae-Hwan Lim
Journal:  Int J Cardiovasc Imaging       Date:  2015-10-26       Impact factor: 2.357

Review 5.  Are we aware of stent fracture?

Authors:  R D Acar; M Bulut; M Akcakoyun
Journal:  Herz       Date:  2013-10-25       Impact factor: 1.443

6.  A ticking time bomb?: a case report of very late stent thrombosis more than 2 years after fracture of a Cypher stent.

Authors:  Sea Hing Ong; Ralf Mueller; Peter Boekstegers
Journal:  Clin Res Cardiol       Date:  2011-07-03       Impact factor: 5.460

7.  Impact of the bifurcation angle on major cardiac events after cross-over single stent strategy in unprotected left main bifurcation lesions: 3-dimensional quantitative coronary angiographic analysis.

Authors:  Kisaki Amemiya; Takenori Domei; Masashi Iwabuchi; Shinichi Shirai; Kenji Ando; Masahiko Goya; Hiroyoshi Yokoi; Masakiyo Nobuyoshi
Journal:  Am J Cardiovasc Dis       Date:  2014-12-29

8.  Complete fracture of sirolimus-eluting stent in a saphenous vein graft to left anterior descending artery.

Authors:  Sun Hong Yoo; Seung Won Jin; Sung Ho Her; Hee Jeoung Yoon; Hyoung Doo Kim; Yun Sun Im; Ki Bae Seung; Jae Hyung Kim
Journal:  Korean Circ J       Date:  2009-06-30       Impact factor: 3.243

Review 9.  Intravascular foreign bodies: danger of unretrieved fragmented medical devices.

Authors:  Minori Tateishi; Yasuko Tomizawa
Journal:  J Artif Organs       Date:  2009-06-18       Impact factor: 1.731

10.  Late thrombosis of sirolimus-eluting stent: a multifactorial problem.

Authors:  Igor Kranjec; Andreja Cerne
Journal:  Case Rep Med       Date:  2009-11-04
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.