Initial experience with the world's first digital drainage system. The benefits of recording air leaks with graphic representation.

Leif Dernevik1, Ali Belboul, Göran Rådberg.   

Abstract

OBJECTIVE: To evaluate the clinical efficacy of a new digital drainage system, the DigiVent Chest Drainage System that gives accurate measurements of air leakage and pleural pressures and can display those measurements over time.
METHODS: The DigiVent Chest Drainage System was tested in three steps: Step 1; first clinical use in five patients, Step 2; management and acceptance in further 15 patients and Step 3; reliability in routine use in 50 patients. RESULT: The results from Steps 1 and 2 showed that the system was good enough for extended use. The results from Step 3 showed excellent clinical performance, however, we experienced device malfunctions in four cases without any consequences for the patients. The cause of the malfunctions was identified and steps taken to prevent their further occurrence.
CONCLUSION: The ability of the DigiVent to measure airflow and present mean values for 1, 3 and 6h proved to be very practical. The ability to save data and present curves for the entire course of treatment will be an advantage for research in the field of lung surgery.

Entities:  

Mesh:

Year:  2006        PMID: 17194600     DOI: 10.1016/j.ejcts.2006.10.038

Source DB:  PubMed          Journal:  Eur J Cardiothorac Surg        ISSN: 1010-7940            Impact factor:   4.191


  11 in total

1.  The application of capnography to differentiate peri-chest tube air leak from parenchymal leak following pulmonary surgery.

Authors:  Jonathan D Oparka; William S Walker
Journal:  Ann Cardiothorac Surg       Date:  2014-03

Review 2.  Advances in chest drain management in thoracic disease.

Authors:  Robert S George; Kostas Papagiannopoulos
Journal:  J Thorac Dis       Date:  2016-02       Impact factor: 2.895

3.  Clinical Evaluation and Outcomes of Digital Chest Drainage after Lung Resection.

Authors:  Fumihiro Shoji; Shinkichi Takamori; Takaki Akamine; Gouji Toyokawa; Yosuke Morodomi; Tatsuro Okamoto; Yoshihiko Maehara
Journal:  Ann Thorac Cardiovasc Surg       Date:  2016-11-23       Impact factor: 1.520

4.  The usefulness of Wi-Fi based digital chest drainage system in the post-operative care of pneumothorax.

Authors:  Hyun Min Cho; Yoon Joo Hong; Chun Sung Byun; Jung Joo Hwang
Journal:  J Thorac Dis       Date:  2016-03       Impact factor: 2.895

5.  A prospective randomized trial comparing homologous and autologous fibrin sealants for the control of alveolar air leak.

Authors:  Burcu Kılıç; Ezel Erşen; Ahmet Demirkaya; H Volkan Kara; Nurlan Alizade; Mehlika İşcan; Kamil Kaynak; Akif Turna
Journal:  J Thorac Dis       Date:  2017-09       Impact factor: 2.895

6.  Pathophysiological mechanism of post-lobectomy air leaks.

Authors:  Aaron R Casha; Luca Bertolaccini; Liberato Camilleri; Alexander Manche; Marilyn Gauci; Gor Melikyan; Ruben Gatt; Krzysztof Dudek; Piergiorgio Solli; Joseph N Grima
Journal:  J Thorac Dis       Date:  2018-06       Impact factor: 2.895

7.  A pilot study of a digital drainage system in pneumothorax.

Authors:  Georgia Tunnicliffe; Adrian Draper
Journal:  BMJ Open Respir Res       Date:  2014-11-04

8.  Complications after Chest Tube Removal and Reinterventions in Patients with Digital Drainage Systems.

Authors:  Yi-Ying Lee; Po-Kuei Hsu; Chien-Sheng Huang; Yu-Chung Wu; Han-Shui Hsu
Journal:  J Clin Med       Date:  2019-12-01       Impact factor: 4.241

9.  Use of a sealant to prevent prolonged air leaks after lung resection: a prospective randomized study.

Authors:  Cosimo Lequaglie; Gabriella Giudice; Rita Marasco; Aniello Della Morte; Massimiliano Gallo
Journal:  J Cardiothorac Surg       Date:  2012-10-08       Impact factor: 1.637

10.  Assessment of pleural air leakage using digital chest drainage system after surgical pulmonary resection: Comparison of visible alveolar air leakage with the digital value measured by a digital chest drainage system.

Authors:  Ryo Mori; Koji Yamazaki; Fumihiro Shoji; Hidenori Kouso; Chie Ushijima; Naoko Miura; Tomoyoshi Takenaka; Sadanori Takeo
Journal:  PLoS One       Date:  2017-11-06       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.