Literature DB >> 17185362

Novel biosensor-based analytic device for the detection of anti-double-stranded DNA antibodies.

Alexander Buhl1, Jochen H Metzger, Niels H H Heegaard, Philipp von Landenberg, Martin Fleck, Peter B Luppa.   

Abstract

BACKGROUND: Patients with systemic lupus erythematosus (SLE) develop a wide variety of serologic manifestations, including double-stranded DNA autoantibodies (anti-dsDNA). The determination of the potentially pathogenic autoantibodies is diagnostically relevant.
METHODS: We developed a novel surface plasmon resonance (SPR) biosensor chip for studies of dsDNA and anti-dsDNA binding. A synthetic oligonucleotide was coupled to biotinylated human transferrin, hybridized with the complementary antistrand, and ligated with a human recombinant dsDNA fragment 233 bp in length. After surface immobilization of this antigenic construct, diluted sera from SLE patients and healthy donors were analyzed with the resulting SPR biosensor system.
RESULTS: This SPR biosensor allowed specific detection of anti-dsDNA. In pilot experiments, sera from SLE patients were distinguished from control sera. We also confirmed the specificity of this biosensor by supplementing anti-dsDNA-positive sera with salmon sperm DNA, which blocked the surface binding of anti-dsDNA in a concentration-dependent manner.
CONCLUSIONS: An SPR biosensor monitors interactions in real time under homogeneous conditions, providing information about binding kinetics and affinities. Its applicability critically depends on the design of the solid-state surface of the sensor chips. Covalently immobilizing dsDNA as the antigen to the surface in a flow-through cell assured maximal stability for multiple serum injections and regeneration cycles. This technique, which adds a new analytic quality to existing methods, may be beneficial in the diagnosis and clinical monitoring of SLE.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17185362     DOI: 10.1373/clinchem.2006.077339

Source DB:  PubMed          Journal:  Clin Chem        ISSN: 0009-9147            Impact factor:   8.327


  6 in total

1.  An Overview on Novel Microbial Determination Methods in Pharmaceutical and Food Quality Control.

Authors:  Mahboob Nemati; Aliasghar Hamidi; Solmaz Maleki Dizaj; Vahid Javaherzadeh; Farzaneh Lotfipour
Journal:  Adv Pharm Bull       Date:  2016-09-25

2.  Comparison and evaluation of different methodologies and tests for detection of anti-dsDNA antibodies on 889 Slovenian patients' and blood donors' sera.

Authors:  Polona Zigon; Katja Lakota; Sasa Cucnik; Tinka Svec; Ales Ambrozic; Snezna Sodin-Semrl; Tanja Kveder
Journal:  Croat Med J       Date:  2011-12-15       Impact factor: 1.351

Review 3.  Detection of autoantibodies in a point-of-care rheumatology setting.

Authors:  Konstantin N Konstantinov; Antonios Tzamaloukas; Robert L Rubin
Journal:  Auto Immun Highlights       Date:  2013-05-18

Review 4.  Construction and Potential Applications of Biosensors for Proteins in Clinical Laboratory Diagnosis.

Authors:  Xuan Liu; Hui Jiang
Journal:  Sensors (Basel)       Date:  2017-12-04       Impact factor: 3.576

Review 5.  Biosensors in clinical chemistry - 2011 update.

Authors:  Paul D'Orazio
Journal:  Clin Chim Acta       Date:  2011-06-26       Impact factor: 3.786

Review 6.  Automated analytical microarrays: a critical review.

Authors:  Michael Seidel; Reinhard Niessner
Journal:  Anal Bioanal Chem       Date:  2008-05-27       Impact factor: 4.142

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.