Abstract

Advances in technology have reduced the risk of fracture of ceramic total hip arthroplasty implants, but concerns remain about fracture of both components. We retrospectively reviewed 133 patients (157 hips) who had cementless alumina-on-alumina total hip arthroplasties with a sandwich-type acetabular component. Six patients (seven hips) died and five patients (six hips) were interviewed by telephone (95% followup). The 122 patients (144 hips) examined had a minimum followup of 36 months (average, 45 months; range, 36-68 months). All acetabular cups and femoral stems were radiographically stable at the last followup. Five hips in five patients (3.5%) were revised because of ceramic liner fractures. Ceramic liner fractures occurred at a mean of 35 months (range, 24-48 months) postoperatively. Acetabular cups in the fracture group (n = 5) were more anteverted than those in the nonfracture group (n = 139). In three patients the fracture apparently occurred during squatting, resulting in hyperflexion and wide hip abduction. Early ceramic liner fracture was associated with impingement associated with excessive anteversion of the acetabular cup in Korean patients who habitually squat.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17179781     DOI: 10.1097/BLO.0b013e3180303e87

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  36 in total

1.  Highly crosslinked polyethylene reduces wear in total hip arthroplasty at 5 years.

Authors:  Jonathan Mutimer; Peter A Devane; Kathryn Adams; J Geoffrey Horne
Journal:  Clin Orthop Relat Res       Date:  2010-12       Impact factor: 4.176

2.  Incidence of ceramic liner malseating in Trident acetabular shell.

Authors:  Anna N Miller; Edwin P Su; Mathias P G Bostrom; Bryan J Nestor; Douglas E Padgett
Journal:  Clin Orthop Relat Res       Date:  2009-03-12       Impact factor: 4.176

3.  Fractures of a sandwich ceramic liner at ten year follow-up.

Authors:  Anthony Viste; Julien Chouteau; Romain Desmarchelier; Michel-Henri Fessy
Journal:  Int Orthop       Date:  2011-10-20       Impact factor: 3.075

4.  Experience with sandwich liner and its high rate of failure.

Authors:  John Junghun Shin; Ji-Soo Shin; Jae-Hyun Kim; Sung Kwan Hwang
Journal:  Eur J Orthop Surg Traumatol       Date:  2014-07-16

Review 5.  Hip replacement in the athlete: is there a role?

Authors:  M J Wilson; R N Villar
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-04-12       Impact factor: 4.342

Review 6.  Impingement and dislocation in total hip arthroplasty: mechanisms and consequences.

Authors:  Thomas D Brown; Jacob M Elkins; Douglas R Pedersen; John J Callaghan
Journal:  Iowa Orthop J       Date:  2014

7.  Letter to the editor: High rate of ceramic sandwich liner fracture.

Authors:  Yong-Chan Ha
Journal:  Clin Orthop Relat Res       Date:  2012-11       Impact factor: 4.176

8.  Catastrophic failure of ceramic-on-ceramic total hip arthroplasty presenting as squeaking hip.

Authors:  David Malem; Mathias Thomas Nagy; Sabyasachi Ghosh; Bhavik Shah
Journal:  BMJ Case Rep       Date:  2013-02-20

9.  Alumina inlay failure in cemented polyethylene-backed total hip arthroplasty.

Authors:  Kentaro Iwakiri; Hiroyoshi Iwaki; Yukihide Minoda; Hirotsugu Ohashi; Kunio Takaoka
Journal:  Clin Orthop Relat Res       Date:  2008-02-21       Impact factor: 4.176

10.  THA with Delta ceramic on ceramic: results of a multicenter investigational device exemption trial.

Authors:  William G Hamilton; James P McAuley; Douglas A Dennis; Jeffrey A Murphy; Thomas J Blumenfeld; Joel Politi
Journal:  Clin Orthop Relat Res       Date:  2009-09-19       Impact factor: 4.176

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.