Micro-XRD study of beta-titanium wires and infrared soldered joints.

Masahiro Iijima1, William A Brantley, Naoki Baba, Satish B Alapati, Toshihiro Yuasa, Hiroki Ohno, Itaru Mizoguchi.   

Abstract

OBJECTIVE: The purpose of this study was to investigate the metallurgical phases in beta-titanium soldered joints prepared by infrared soldering, using the Micro X-ray diffraction technique (Micro-XRD), and to characterize the Vickers hardness in the soldered beta-titanium wires.
METHODS: Beta-titanium wires with cross-section dimensions of 0.032in.x0.032in. (TMA, Ormco), and both titanium-based solder (Ti-30Ni-20Cu, Selec) and silver-based solder (Ag-22Cu-17Zn-5Sn, Tomy) were selected. Soldering was performed using infrared radiation (RS-1, Morita) under argon atmosphere. Micro-XRD analyses were performed at room temperature. Micro-XRD spectra were obtained for the boundary region of the soldered beta-titanium wires using 50microm and 10microm diameter analysis regions. Hardness was measured at 30microm intervals from boundary of the diffusion layer and beta-titanium wire. The Kruskal-Wallis test with the Bonferroni and Wilcoxson Mann-Whitney tests for nonparametric means were employed as statistical methods (P<0.05).
RESULTS: For both types of soldered beta-titanium samples, the Micro-XRD spectra contained four major peaks for body-centered cubic (bcc) beta-titanium. Additional peaks at about 41 and 45 degrees are attributed to Cu-Ti intermetallic phase(s), which may be metastable under soldering conditions. The diffusion layer had greater hardness than bulk beta-titanium for both types of soldered specimens (P<0.05). SIGNIFICANCE: Soldering of beta-titanium orthodontic wire by infrared radiation may be acceptable for clinical use, since Micro-XRD spectra revealed that both types of soldered specimens largely retained the bcc beta-titanium structure. Further research is needed to investigate the mechanical properties and corrosion behavior of infrared-soldered beta-titanium wire.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17178150     DOI: 10.1016/j.dental.2006.06.054

Source DB:  PubMed          Journal:  Dent Mater        ISSN: 0109-5641            Impact factor:   5.304


  2 in total

1.  Mechanical properties of orthodontic wires derived by instrumented indentation testing (IIT) according to ISO 14577.

Authors:  Spiros Zinelis; Youssef S Al Jabbari; Marianna Gaintantzopoulou; George Eliades; Theodore Eliades
Journal:  Prog Orthod       Date:  2015-06-19       Impact factor: 2.750

2.  Assessment of the hardness of different orthodontic wires and brackets produced by metal injection molding and conventional methods.

Authors:  Shiva Alavi; Marzie Kachuie
Journal:  Dent Res J (Isfahan)       Date:  2017 Jul-Aug