Literature DB >> 17177707

Patch test frequency to p-phenylenediamine: follow up over the last 6 years.

Sheena Patel1, David A Basketter, Donna Jefferies, Ian R White, Richard J G Rycroft, John P McFadden, Stephanie Y Ho.   

Abstract

While the frequency of patch test reactivity to many cosmetic allergens has decreased over the last 20 years, we have previously shown that in our clinic, the patch test reactivity to p-phenylenediamine (PPD) has remained stubbornly high between 2.5% and 4.2% in the years when patch testing was performed with 1% PPD. Further retrospective analysis of the PPD patch test frequency over the last 6 years shows an increasing rate of PPD patch test frequency, showing an upward linear trend. This increasing trend cannot be fully explained by any increase in patch testing of Southern Asian patients or of sensitization caused by PPD exposure from 'temporary henna tattoos'. An alternative explanation may be the increasing use of permanent hair dyes.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17177707     DOI: 10.1111/j.1600-0536.2007.00779.x

Source DB:  PubMed          Journal:  Contact Dermatitis        ISSN: 0105-1873            Impact factor:   6.600


  8 in total

1.  Allergy to hair dye.

Authors:  John P McFadden; Ian R White; Peter J Frosch; Heidi Sosted; Jenne D Johansen; Torkil Menne
Journal:  BMJ       Date:  2007-02-03

2.  Evaluation of suspected cosmetic induced facial dermatoses with the use of Indian standard series and cosmetic series patch test.

Authors:  Madhur Kant Rastogi; Astha Gupta; Puneet Singh Soodan; Nitin Mishra; Pratik Gahalaut
Journal:  J Clin Diagn Res       Date:  2015-03-01

3.  A laboratory test based on determination of cytokine profiles: a promising assay to identify exposition to contact allergens and predict the clinical outcome in occupational allergic contact dermatitis.

Authors:  Valentina Bordignon; Francesca Palamara; Giorgia Altomonte; Isabella Sperduti; Mario Pietravalle; Claudia Cavallotti; Paola Cordiali-Fei; Maria Pia Fuggetta; Antonio Cristaudo; Fabrizio Ensoli
Journal:  BMC Immunol       Date:  2015-02-06       Impact factor: 3.615

4.  Analysis of the Results from the Patch Test to Para-Phenylenediamine in the TRUE Test in Patients with a Hair Dye Contact Allergy.

Authors:  Jin Yong Lee; Chul Woo Kim; Sang Seok Kim
Journal:  Ann Dermatol       Date:  2015-03-24       Impact factor: 1.444

Review 5.  Para-phenylenediamine allergy: current perspectives on diagnosis and management.

Authors:  Krishna Sumanth Mukkanna; Natalie M Stone; John R Ingram
Journal:  J Asthma Allergy       Date:  2017-01-18

6.  P-Phenylenediamine Hair Dye Allergy and Its Clinical Characteristics.

Authors:  Ju Hee Han; Hyun Ji Lee; Chul Hwan Bang; Ji Hyun Lee; Young Min Park; Jun Young Lee
Journal:  Ann Dermatol       Date:  2018-04-23       Impact factor: 1.444

7.  Paraphenylenediamine and related chemicals as allergens responsible for allergic contact dermatitis.

Authors:  Joanna Bacharewicz-Szczerbicka; Teresa Reduta; Anna Pawłoś; Iwona Flisiak
Journal:  Arch Med Sci       Date:  2019-07-18       Impact factor: 3.318

8.  Angioedema, an unusual reaction to hair dye.

Authors:  Reginald Mzudumile Ngwanya; Zandile Spengane; Nonhlanhla Khumalo
Journal:  Pan Afr Med J       Date:  2018-06-06
  8 in total