Literature DB >> 17176853

[Evaluation of rapid diagnostic kits for the detection of group A streptococcus to Streptococcus pyogenes and Streptococcus spp. with Lancefield's group A antigen].

Noriko Mitsuno1, Tomohiro Hari, Nobuyoshi Tamagawa, Juichi Itoi, Eiji Ikeda, Kazuko Hamasaki, Chihiro Katsukawa, Michiko Okuyama.   

Abstract

We studied the basic performance of eight rapid diagnostic kits for the detection of Group A streptococcus by immunochromatography under the same conditions. Kits were the; QuickVue Dipstick Strep A (Sumitomo Seiyaku Biomedical Co., Ltd.), TESTPACK Plus STREP A (ABBOTT JAPAN Co., Ltd), CLEAVIEW STREP A (Nihon Schering K. K.), QuickVue STREP A (Wako Pure Chemical Industries, Ltd), ImmunoCard STAT! STREP A (TFB, INC.), DIPSTICK 'Eiken' STREP A (Eiken Chemical Co., Ltd.), Rapid Testa Strep A (Daiichi Pure Chemical Co., Ltd.), and StatCheck Strep A (KAINOS Laboratories, Inc.). Four of these kits, i.e. QuickVue Dipstick Strep A, TESTPACK Plus STREP A, Rapid Testa Strep A, and StatCheck Strep A showed sensitivity at 1.0 x 10(5) CFU/mL (1.0 x 10(4)CFU/test) with all of S. pyogenes tested, while the Anginosus group and S. dysgalactiae subsp. equisimilis with Lancefield' s group A antigen showed sensitivity very similar to S. pyogenes. Of these strains, S. dysgalactiae subsp. equisimilis formed a beta-hemolytic colony resembling that of S. pyogenes on sheep blood agar, and was sensitive to bacitracin. It is thus indispensable to identify the colony using biochemical tests such as the PYR (pyrrolidonylarylamidase production) test. In using rapid diagnostic kits for the detection of Group A streptococcus, it is important to rule out the possibility of Group A streptococcus other than S. pyogenes in throats. Severe invasive group-G streptococcal infections are increasing recently. Concerning S. dysgalactiae subsp. equisimilis, it is especially important to conduct these identification tests.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17176853     DOI: 10.11150/kansenshogakuzasshi1970.80.665

Source DB:  PubMed          Journal:  Kansenshogaku Zasshi        ISSN: 0387-5911


  1 in total

1.  Development of an immunochromatographic assay specifically detecting pandemic H1N1 (2009) influenza virus.

Authors:  Tohru Miyoshi-Akiyama; Kenji Narahara; Sunao Mori; Hirotake Kitajima; Tetsuo Kase; Saeko Morikawa; Teruo Kirikae
Journal:  J Clin Microbiol       Date:  2010-01-13       Impact factor: 5.948

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.