Literature DB >> 17174962

Lowering the concentration limits of detection by on-line solid-phase extraction-capillary electrophoresis-electrospray mass spectrometry.

Fernando Benavente1, M Cristina Vescina, Elena Hernández, Victoria Sanz-Nebot, José Barbosa, Norberto A Guzman.   

Abstract

The use of solid-phase extraction coupled on-line to capillary electrophoresis using electrospray mass spectrometry detection (SPE-CE-ESI-MS) is described for the analysis of peptides in dilute solutions. A SPE microcartridge or analyte concentrator containing C(18) derivatized silica particles as the extraction sorbent was easily constructed near the inlet of the separation capillary using commercially available materials. The reversed-phase sorbent selectively retained the target peptides, enabling large volumes of the sample to be introduced (>100muL). The captured analytes were eluted in a small volume of an appropriate solution (20-50nL). This resulted in sample clean-up and concentration enhancement, with minimum sample handling. As the SPE-CE conditions were compatible with on-line ESI-MS detection, the potential for identifying and characterizing the preconcentrated analytes by SPE-CE-ESI-MS using a sheath-flow CE-ESI-MS interface is also shown. Using separation electrolytes containing N-[carbamoylmethyl]-2-aminoethanesulfonic acid (ACES) at pH 7.4, an elution plug of 80:20 (v/v) (25mM of formic acid in MeCN):H(2)O and a sheath liquid of 20mM of acetic acid in 50:50 (v/v) methanol:H(2)O the concentration limits of detection for the analyzed peptides in the positive ion mode were lowered to nanogram per milliliter levels. The systematic optimization of the operational parameters involved in the development of the SPE-CE method is described in detail, in order to promote robust and quantitative SPE-CE-ESI-MS analysis and facilitate the widespread use of the technique.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17174962     DOI: 10.1016/j.chroma.2006.11.092

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  3 in total

1.  Detachable strong cation exchange monolith, integrated with capillary zone electrophoresis and coupled with pH gradient elution, produces improved sensitivity and numbers of peptide identifications during bottom-up analysis of complex proteomes.

Authors:  Zhenbin Zhang; Xiaojing Yan; Liangliang Sun; Guijie Zhu; Norman J Dovichi
Journal:  Anal Chem       Date:  2015-04-10       Impact factor: 6.986

2.  Integrated strong cation-exchange hybrid monolith coupled with capillary zone electrophoresis and simultaneous dynamic pH junction for large-volume proteomic analysis by mass spectrometry.

Authors:  Zhenbin Zhang; Liangliang Sun; Guijie Zhu; Xiaojing Yan; Norman J Dovichi
Journal:  Talanta       Date:  2015-02-10       Impact factor: 6.057

Review 3.  Immunoaffinity capillary electrophoresis as a powerful strategy for the quantification of low-abundance biomarkers, drugs, and metabolites in biological matrices.

Authors:  Norberto A Guzman; Timothy Blanc; Terry M Phillips
Journal:  Electrophoresis       Date:  2008-08       Impact factor: 3.535

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.